Configuring the Jumpers
Configuring the Jumpers
For additional flexibility, your thermostat has three configurable
outputs. These outputs are designed to have different functions
depending on how the jumpers are set (below).
Each output, labeled MISC1, MISC2, and MISC3 may be set for one
of the four choices available.
In the diagram below, the MISC3 jumper has been set for HUM
(humidification) operation, the MISC2 jumper has been set for DEHUM
(dehumidification) operation, and the MISC1 jumper has been set for
Y2 (second stage cooling) operation.
ELEC
GAS
HP
HUM
GAS
DEHUM
Y2
B
(MISC1
MISC3
MISC2
MISC1
ONLY)
O
W1
W2
Y1
MISC1
G
RS2
MISC2
MISC3
CK1
RS+5
CKGND
RS1
R
INSTALL HUMIDITY
MODULE WITH SENSING
RSGND
ELEMENT OUTWARD
C
CAUTION
NEVER PUT MORE THAN
ONE JUMPER ON THE SAME
MISC JUMPER BLOCK!
DOING SO MAY DAMAGE
YOUR THERMOSTAT AND
VOID THE WARRANTY.
HUM
DEHUM
MISC3
MISC2
MISC1
MISC1