Fig. 2: Dismantled camera bracket
Fig. 3 Mounting the camera to the bracket
The first access to the camera
•
After connecting the camera to the power supply and the data network the camera can be accessed via a web
browser; the camera starts about 60 seconds.
•
The default setting of the camera:
IP address:
o
User name:
o
Password:
o
•
The camera can be found on the network using the application of the recording software iVMS-4200 on the
attached CD or can be downloaded at
•
Run the installation file from the CD (as a standard iVMS-4200.exe), accept the license agreement and follow the
instructions on the screen
•
After installation run the software iVMS-4200 Client and log in - default login data:
User name:
o
Password:
o
•
After logging in, use the "Settings" menu on the top bar and select the "Device Management"
•
In the application a panel opens for configuring the devices managed by the recording software iVMS-4200
•
In the upper left part click on the tab "Server" and select "DVR, IPC, Encoder" from the list
•
In the bottom right part you will now see the available cameras on the network ("Online Device") - see Fig. 5
3
IMAGO ICN-x1P1 NW 2.8 (W) – Quick Installation Guide
192.0.0.64 (DHCP Client enabled)
admin
12345
www.imago-video.com
admin
choose your own password when loging-in for the first time
Fig. 4 Mounting the camera to the
bracket
www.imago-video.com