Installing The Ceiling Bracket - Hunter Roswell Installation Manual

Table of Contents

Advertisement

You have two options for installation. Pick which one works best for your location. Remove
any existing bracket prior to installation. Only use the provided Hunter ceiling bracket that
came in your fan's box.
Do this first!
OFF
Option 1:
Machine Screws
Use machine screws (provided
with outlet box) and washers
when securing to existing ceiling
fan-rated outlet box. Make sure
it is securely installed and is
acceptable for fan support of 31.8
kg (70 lbs) or less.
For angled ceilings,
point opening
toward peak.
Follow below if you are using the downrod that came pre-assembled in your box. Need to
install a longer or shorter downrod? Check out the guide at the end of this manual.
1
Remove the pre-installed
setscrew so that the
downrod can be inserted.
4
Tighten the setscrew
with pliers. DO NOT
HAND TIGHTEN.
Ceiling Bracket
Downrod

Installing the Ceiling Bracket

Installing the Downrod
Hunter Pro Tip:
2
Pass all wires to one side of horizontal bar in
downrod assembly. Hand tighten the downrod
(at least 4–5 full turns) until it stops. Trim the
wires coming from the fan so that 8-inches
remain coming from the top of the downrod.
Hanging Fan
Wiring
Hunter Pro Tip:
The machine screws are the ones
that came with your outlet box.
Option 2:
Wood Screws
Use wood screws and
washers (included) when
securing to support structure
with approved electrical
outlet box. Drill 9/64" pilot
holes in support structure
to aid in securing ceiling
bracket with hardware found
in the
WARNING
To avoid possible electrical shock, before
installing your fan, disconnect the power by
turning off the circuit breakers to the outlet
box associated with the wall switch location.
The ground wire attached to the
downrod is approximately 8 inches.
Canopy
Blades
hardware bag.
bag
Wood Screw
3
3/8"
8"
The wires can be cut, but leave at least 8"
extending from the top of the downrod.
WARNING
FAN FALL HAZARD
To prevent SERIOUS INJURY or DEATH:
• ALWAYS tighten setscrew with pliers.
• DO NOT hand tighten setscrew.
• CHECK the setscrew is tight using pliers
each time you change fan direction.
Note:
Fan style may vary.
Control
Troubleshooting
1886
x2
Washer
x2
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

5079750798