10. Adjusting the wraps
By default the machine is set for 3 wraps (ULTRA
GRIP 58: 4 wraps). Changing the setting to 2 wraps
(ULTRA GRIP 58: 3 wraps): Turn off the machine
on the main switch. Press and hold the trigger while
turning on the main switch. The machine is now set
for 2 wraps per tie (ULTRA GRIP 58: 3 wraps). If the
machine is turned off, it will automatically be set for 3
wraps again (ULTRA GRIP 58: 4 wraps).
11. The torque setting unit adjusts the tension of the
ties. 1. digit displays the wrap setting and 2. digit dis-
plays the torque setting. The torque can be adjusted
higher
or lower
We recommend:
Model
2 wraps
ULTRA GRIP 25
ULTRA GRIP 40
ULTRA GRIP 58
12. Perform a test tie, to check if the torque is set
correctly.

Correct use

1. Place the arm A unit in a 45° angle over the re-bar
cross surface and push the mouth towards the re-bar.
2. Place Arm A perpendicularly on top of the re-bar
cross surface and with the mouth centred over the
cross.
10
by means of the push buttons.
3 wraps
4 wraps
1 - 5
6 - 9
1 - 5
6 - 9
-
1 - 5
45°
!
!
3. The ties should be made in alternating directions.
4. Cross-tying.
Bend down the knot of the first tie, before you make
the second tie.
-
-
6 - 9

How to replace the wire coil.

!
1. Push the release lever until it is caught by the
release stopper.
Release stopper
2. Remove the wire coil.
WARNING! Do not move the re-bar binder
while it is tying.
WARNING! Set the main switch to OFF po-
sition, activate the trigger lock and remove
the battery.
Release lever
Wire
Pipe

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Tjep 40Tjep 58

Table of Contents