To increase the minimum jet pressure, turn the top ring on the special tool in a clockwise
direction.
The screw of the pressure regulator is tightened by the special tool.
To reduce the minimum jet pressure, turn the top ring on the special tool in a counter-
clockwise direction.
The screw of the pressure regulator is loosened by the special tool.
Insert the plug again.
Fit the cap onto the pressure regulator.
Seal the connection pressure and jet pressure measuring stubs with the locking bolts.
Burners, PT 825x, PT 833x, PT 840x, PT 850x, PT 880x
PT 850x, PT 880x = 2 jets
PT 850x
PT 880x
Jet
Gas
21