Troubleshooting - Hitachi DS 14DBL2 Handling Instructions Manual

Hide thumbs Also See for DS 14DBL2:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
English
NOTE
Due to HITACHI's continuing program of research and
development, the specifi cations herein are subject to
change without prior notice.

TROUBLESHOOTING

Use the inspections in the table below if the tool does not operate normally. If this does not remedy the problem, consult your
dealer or the Hitachi Authorized Service Center.
Symptom
Tool doesn't run
Tool suddenly stopped
Tool bits
-can't be attached
-fall off
Switch can't be pulled
Screw head slips or comes
loose.
Holes can't be smoothly
drilled.
The charge indicator lamp
is rapidly blinking purple,
and battery charging
doesn't begin.
The charge indicator lamp
blinks red, and battery
charging doesn't begin.
Battery usage time is short
even though the battery is
fully charged.
The battery takes a long
time to charge.
The USB power lamp
has switched off and the
USB device has stopped
charging.
USB power lamp does not
switch off even though the
USB device has fi nished
charging.
Possible cause
No remaining battery power
Battery isn't securely attached.
Tool was overburdened
Reactive force control was activated
Battery or tool overheated
The shape of the attachment portion doesn't
match
The lock of the keyless chuck is worn
Forward/reverse selector button is
positioned halfway
Bit number doesn't match with the screw
size
The bit is worn
The drill is worn
Rotation speed isn't appropriate
The drill is rotating in reverse
The battery is not inserted all the way.
There is foreign matter in the battery
terminal or where the battery is attached.
The battery is not inserted all the way.
The battery is overheated.
The battery's life is depleted.
The temperature of the battery, the charger,
or the surrounding environment is extremely
low.
The charger's vents are blocked, causing its
internal components to overheat.
The cooling fan is not running.
The battery's capacity has become low.
The USB power lamp lights up green to
indicate that USB charging is possible.
Charge the battery.
Push in the battery until a click is heard.
Remove the cause of the overburdening.
See "Reactive force control".
Allow the tool and battery to thoroughly cool.
The chucking diameter of the keyless chuck
is 1.5 mm to 13 mm. Use a bit that falls
within the stated range.
Contact a Hitachi Authorized Service Center
and arrange to have the old keyless chuck
replaced with a new one.
Press the button fi rmly into position for the
desired direction of rotation.
Install a suitable bit.
Replace with a new bit.
Replace with a new drill.
Adjust the rotation speed (HIGH/LOW) to
match the material to be drilled.
Switch to forward rotation.
Insert the battery fi rmly.
Remove the foreign matter.
Insert the battery fi rmly.
If left alone, the battery will automatically
begin charging if its temperature decreases,
but this may reduce battery life. It is
recommended that the battery be cooled in
a well-ventilated location away from direct
sunlight before charging it.
Replace the battery with a new one.
Charge the battery indoors or in another
warmer environment.
Avoid blocking the vents.
Contact a Hitachi Authorized Service Center
for repairs.
Replace the battery with one that has
capacity remaining.
Plug the charger's power plug into an
electric socket.
This is not a malfunction.
10
Remedy

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds 18dbl2Dv14dbl2Dv18dbl2

Table of Contents