Page 1
Model 1204-12A/084A101 PCB L&T load cell, low profile, 25,000 lbf rated capacity, 50% overload Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-828-8840 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com...
Page 2
Piezotronics, user servicing or repair is critical test. not recommended and, if attempted, may void the factory warranty. Routine PCB Piezotronics maintains an ISO- maintenance, such as the cleaning of 9001 certified metrology laboratory and electrical connectors, housings, and offers calibration services, which are...
Page 3
E-mail: info@pcb.com representative. Warranty – All equipment and repair services provided by PCB Piezotronics, Inc. are covered by a limited warranty against defective material workmanship for a period of one year from date of original purchase. Contact...
Page 5
Component Name Hazardous Substances Lead Mercury Cadmium Chromium VI Polybrominated Polybrominated (Pb) (Hg) (Cd) Compounds Biphenyls Diphenyl (Cr(VI)) (PBB) Ethers (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
Page 6
Model Number Revision: B LOW PROFILE LOAD CELL 1204-12A ECN #: 43809 Performance ENGLISH OPTIONAL VERSIONS Measurement Range 25 klbf 111 kN [6][7] Optional versions have identical specifications and accessories as listed for the standard model Sensitivity(± 10 %)(RO) 4.0 mV/V 4.0 mV/V...
GENERAL PURPOSE LOW PROFILE LOAD CELL OPERATION MANUAL 3.1 Dimensions 1.0 INTRODUCTION The following figure and tables give the general outline General purpose low profile load cells manufactured by PCB dimensions of the general purpose low profile load cells with Load &...
GENERAL PURPOSE LOW PROFILE LOAD CELL OPERATION MANUAL 3.2 Standard Components NOTE: The use of the tension base greatly increases the performance of the low profile load cell. The following figure describes the standard components of the general purpose low profile load cells. 4.0 MECHANICAL INSTALLATION Load Cell The following mechanical installation instructions should be...
GENERAL PURPOSE LOW PROFILE LOAD CELL OPERATION MANUAL 5.2 Cable & Grounding Considerations Proper grounding and shielding is required to prevent electrical noise in strain gage load cell measuring systems. The cable must be shielded twisted pairs with a drain wire. Cable shields must be grounded only at one end, for example, on the instrument or control system ground.
GENERAL PURPOSE LOW PROFILE LOAD CELL OPERATION MANUAL 6.1.1 Measured Output 7.0 MOMENT COMPENSATION The applied load starting at zero is measured in five When an eccentric axial load is increments to full scale. Output (mV/V) is measured at each applied to a load cell that is not Primary increment.
GENERAL PURPOSE LOW PROFILE LOAD CELL OPERATION MANUAL are not allowed to migrate into devices that are not Check bridge balance. hermetically sealed. Such devices should only be wiped with a damp cloth, and never be submerged or have liquids poured 10.
GENERAL PURPOSE LOW PROFILE LOAD CELL OPERATION MANUAL Standard calibration certificates list five force points ascending and one point descending in both tension and compression. Additional data points are available at extra cost upon request. Certificate information includes tabulated measurement variable data zero balance, bridge input/output resistance, computer nonlinearity and hysteresis, static error band (SEB) calculations and entries abilities and traceability statements.