FAIL-SAFE
VRGC
2VRGC
1 ' x 4 ' , 2 ' x 2 ' , 2 ' x 4 '
1 , 2 , 3 , O R 4 L A M P
VA N D A L R E S I S TA N T
L U M I N A I R E
• Nominal 41/2" deep
paracontoured housing,
die formed code gauge,
prime cold rolled steel
• Finish is lighting grade
baked white enamel
• Die formed, heavy gauge,
flat steel door with
reinforced mitered corners
and baked white enamel
finish. Positive light seals.
Frame and lens are secured
to housing with 4 or 6
®
stainless steel TORX
screws
• Positive cam action spring
loaded steel latches with
baked white enamel finish
• Ballasts are CBM/ETL Class
"P" and positively secured
by mounting bolts.
Pressure lock lampholders
1430
COOPER LIGHTING
®
D E S C R I P T I O N
The Fail-Safe VRGC and 2VRGC
Series fluorescent luminaires
feature recessed aesthetics and
the latest in energy-efficient
technology. Their Energy
Saving Ballast complies with
Federal Energy Standards.
Features include a die-
embossed housing, four
convenient end suspension
points, and high comfort
photometrics. U.L. listed and
C.S.A. certified.
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : 2 V R G C - 2 3 2 A - 1 2 0 V - E B 8 1 - U
Width
Blank=1'
2=2'
Product Family
VR
Trim Type
1
G=Grid/Lay-in – Standard
G=Concealed T
G=Slot Grid
F=Flange Trim
MZ=Modular Trim
EMZ=Modular Trim (Extended
Swing Arm)
Series
C
Door Type
Standard=Flat White Steel Door
(Leave Blank)
NOTE: For additional options, consult your Cooper Lighting Representative. Specifications and Dimensions subject to change without notice.
1
Consult Pre Sales Technical Support.
ceiling systems.
D I M E N S I O N S
M O U N T I N G
B
C
B
C
Number of Lamps
1, 2, 3, or 4 lamps
(Not included)
Wattage (Length)
U3=40W (24")
U6=40W (24")
U6T8=31W (24")
20=20W (24")
17=17W (24")
U1-5/8=31W
T8 (24")
BX40=40W
Biax (24")
40=40W (48")
32=32W T8 (48")
Lens Type
ACTF140= .140 Thick
ACTF187= .187 Thick
PA375= .250 polycarbonate
with .125 prismatic
overlay
(standard with 6S
option)
2
Two ballast in 2 or 4 lamp require LAO (less access opening).
B
A
B
VRGC
5 5/8"
11 3/4"
(1' x 4')
(143mm)
(298mm)
2VRGC
4 5/8"
23 3/4"
(2' x 2')
(117mm)
(603mm)
2VRGC
4 5/8"
23 3/4"
(2' x 4')
(117mm)
(603mm)
Voltage
Voltage
1
Options
(order as suffix)
LTS=Low
120=120V
PAF=Painted After
Trigger Start
277=277V
Fabrication
(20 Watt)
347=347V
GL=Internal Single
HTS=High
UNV=
Element Fusing
Trigger Start
Universal
GM=Dual Element
(20 Watt)
Voltage
Fusing
120-277V
LCWE=F40/Cool White
Energy Saving Lamps,
Ballast Type
Installed
Standard Magnetic Ballast
L8730=F32T8 3000
Leave Blank (Biax Only)
Kelvin Lamps, Installed
LE3=
Energy Saving Ballast
L8735=F32T8 3500
Kelvin Lamps, Installed
LEOC8= Energy Saving Ballast
L8741=F32T8 4100
(T-8 Lamp Only)
Kelvin Lamps, Installed
EB _ _= Generic Electronic
EL4=Emergency
Ballast
Lighting self-contained
No. of Ballasts
RIF1=Radio Interference
1 or 2
2
Suppressor
Lamp Size
FR=Suitable for Fire
2=T12
Rated Applications
8=T8
EQ=T-BAR Safety
Earthquake Clips
(For Specific Electronic Ballast
RLS=Rotor-Lock Socket
Specify Brand and Catalog
(T8 Lamps Only)
Number)
6S=Six TORX-head
Screws(3 per side)
SC=Safety Chain
3
EQ Grid Clip is recommended for all 9/16"
A
C
48"
(1219mm)
24"
(610mm)
48"
(1219mm)
1
3

Advertisement

loading

This manual is also suitable for:

Fail-safe vrgcFail-safe vrgc series