MAINTENANCE

1. For safe and proper working, always keep the machine and
ventilation slots clean.
2. A damaged dust protection cap should be changed immediately.
We recommend having this carried out by an after-sales service.
3. Approximately every 10 hours of operation, please check the
grease reservoir as follow steps:
a) Lift the tap of oil seal cap (9), loosen the cap counter clockwise
with fingers to open the grease reservoir.
b) Remove the corresponding amount of grease from container
and press it into the reservoir.
c) Replace the oil seal cap to the grease reservoir and secure it
by turning clockwise.
4. Worn carbon brushes are to be replaced only by a specialist
workshop. It is recommended that you take this tool to a Ryobi
Authorized Service Center for a through cleaning and lubrication
at least once a year.
It is recommended that you take this tool to a Ryobi Authorized
Service Center for a through cleaning and lubrication at least once
a year.
DO NOT MAKE ANY ADJUSTMENTS WHILE THE MOTOR IS IN
MOTION.
ALWAYS DISCONNECT THE POWER CORD FROM THE
RECEPTACLE BEFORE CHANGING REMOVABLE OR
EXPENDABLE PARTS (BLADE, BIT, SANDING PAPER ETC.),
LUBRICATING OR WORKING ON THE UNT.
CAUTION!
USE ONLY THE GREASE APPROVED BY RYOBI FOR THE
PRODUCT. OTHER GREASE CAN BE DAMAGE YOUR PRODUCT.
WARNING!
To ensure safety and reliability, all repairs should be performed
by an AUTHORIZED SERVICE CENTER or other QUALIFIED
SERVICE ORGANIZATION.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.