OMB-AI-EXP32 User's Guide
Expansion connector
The OMB-AI-EXP32 has a 37-pin male DSUB connector that connects directly to the 37-pin female DSUB
connector on a OMB-DAQ-2416 series module.
Information on signal connections
General information regarding signal connection and configuration is available in the Guide to Signal
Connections. This document is available in the Documents subdirectory where you installed the software.
Associating CJC channels with thermocouple channels
TC channels must immediately follow their associated CJC channels in the channel array. For accurate
thermocouple measurements, associate CJC channels with the TC channels as listed below.
When measuring thermocouples, configure the OMB-DAQ-2416 series module for differential inputs.
EGND.....
NC.....
DIO_LOAD1.....
DIO_LOAD2.....
IMEN7.....
IMEN8.....
IMEN9.....
IMEN10.....
IM_A0.....
IM_A1.....
IM_A2.....
NC.....
NC.....
VCC.....
AGND.....
EXP_CH.....
AGND.....
EXP_CL.....
AGND.....
Figure 5. DSUB37 expansion connector pin out
CJC channels
CJC6
CJC7
CJC8
CJC9
CJC10
CJC11
.....EGND
.....NC
.....SCK
.....MOSI
.....SDA
.....SCL
.....CM_A2
.....SM_A0
.....SM_A1
.....CM_A3
.....EXTDIO_INT
.....VDD_ISO
.....-20.5 V
.....AGND
.....+20.5 V
.....+5 VA
.....AGND
.....+3.3 V_ISO
TC channels
TC8 through TC11
TC12 through TC15
TC16 through TC19
TC20 through TC23
TC24 through TC27
TC28 through TC31
10