Brennenstuhl RCS 1000 N - RF Remote Control Switch Set Manual

Brennenstuhl RCS 1000 N - RF Remote Control Switch Set Manual

Also See for RCS 1000 N:

Advertisement

Brennenstuhl RCS 1000 N - RF Remote Control Switch Set Manual

Intended use

The devices which constitute this RF remote control switch set are intended only for personal use in closed dry rooms. They are not suitable for commercial use. The RF remote control switch set is used for switching lamps and electrical appliances on and off. The devices may only be operated individually.

Do not plug multiple socket switches into each other. Any other use is considered non-intended use. The manufacturer assumes no liability for damage caused by non-intended use.

Operating manual

Read this operating manual through thoroughly before using the device. Keep the operating manual in a safe place. Should you pass on this device to another party be sure to include the operating manual.

Basic safety instructions

  • Children are not aware of the dangers that may arise from improper handling of electrical devices. Never allow children to use electrical devices without supervision.
  • Risk of suffocation! Do not leave the packaging material lying around. Children could swallow the small parts and choke on them.
  • Plug the socket switches into conventional 220-240VAC/50Hz two-pin earthed sockets only.
  • Do not connect the socket switches to extension cables.
  • Only connect consumers which do not exceed the performance limits of the socket switches.
  • Do not connect consumers (for example irons) which could cause fire or other damage if they are accidentally switched on.
  • Do not connect consumers (for example refrigerators) which require condenser motors.
  • Do not cover the socket switches. Heat builds up under the cover. This poses a fire hazard.
  • Regularly check the devices for damage. Do not replace damaged parts. Contact the manufacturer or dispose of the devices in an environmentally friendly manner.
  • Do not touch the devices with wet hands.
  • To de-energise the socket switches disconnect them from the mains supply.

Synchronising the system code

Before using the devices for the first time the system code must be synchronised to enable all socket switches to react to the radio signal of the remote control. Moreover, each socket switch must be assigned a frequency of a key pair on the remote control to enable it to be operated individually.

information Adjust the DIP switches using a suitable object, for instance a small screwdriver, by pushing them down or up.

Setting a system code on the socket switch

Setting a system code on the socket switch

  1. Socket switch
  2. Childproof two-pin earthed socket
  3. Two-pin earthed plug
  4. Function indicator light
  5. Screw hole
  6. Cover
  7. DIP switches
  8. Thread
  9. Screw
  1. Undo the screw of the cover using a PH0 Phillips screwdriver.
  2. Slightly raise the cover above the screw hole and push out.
  3. Set the same system code as for the App using DIP switches 1 to 5 .

Assigning a socket switch to a control key

Assigning a socket switch to a control key

  1. Set a control key on the remote control using DIP switches A to E :
    information DIP switch E is not occupied.
    Control key DIP switch
    A B C D E
    A ON OFF OFF OFF OFF
    B OFF ON OFF OFF OFF
    C OFF OFF ON OFF OFF
    D OFF OFF OFF ON OFF
  2. Push the cover in and close.
  3. Insert the screw through the screw hole into the thread and tighten.

Switching on a socket switch

  1. Plug the socket switch into a socket.
  2. Plug the consumer into the two-pin earthed socket .
  3. Switch the socket switch via app on.
    The function indicator light illuminates.

Switching off a socket switch

Switch the socket switch via app off.

The function indicator light goes out.

Connecting the devices

The radio signal has a range of up to 25 m (dependent on structural conditions).

information The range can be affected by structural conditions (for example reinforced concrete), electrical conditions (for example electrical lines) or electromagnetic conditions (for example telephones). If necessary remove the source of interference or maintain a suff cient distance to the source of interference.

Technical data

Operating voltage: 230 VAC 50 Hz
Switching voltage: 230 VAC 4,35 A
Socket switch switching power: max. 1000 W
Radio signal range: max. 25 m
Operating frequency: 433.92 MHz
Ambient temperature: 0°C to 35°C
Storage temperature: -40°C to 70°C
CE-compliant:

Troubleshooting

Fault Possible cause Remedy
Function indicator light does not light up. Socket switch has not been connected correctly. Push the socket switch firmly into the socket.
Function indicator light lights up, but consumer does not work. Consumer has not been switched on. Switch on the consumer.
Socket switch does not switch on. System code of the socket switch has not been set correctly. Set the system code of the App and on the socket switch.
Electrical devices are causing interference. Remove possible sources of interference.

Cleaning


Risk of electric shock.
Before cleaning the device disconnect it from the mains supply. Ensure that no liquid penetrates into the device.
Liquid which enters the device can cause short-circuiting.


Risk of damage from aggressive cleaning agents.
Never use aggressive or abrasive cleaning agents for cleaning. Clean the device with a soft damp cloth and a mild cleaning agent. Ensure that the device is completely dry before using it again.

Waste disposal


Dispose of electrical devices in an environmentally friendly manner!
Electrical devices do not belong in the household rubbish. In accordance with European Directive 2002/96/EC on waste electrical and electronic equipment old power tools must be collected separately and sent to a proper recycling facility. You can found out more about the options for disposing of used devices from your local government or municipal authorities.

Conformity declaration

Hugo Brennenstuhl GmbH & Co. KG
Seestraße 1-3 · D-72074 Tübingen

H. Brennenstuhl S.A.S.
Z.A. 5 rue de l'Artisanat
F-67460 Souffelweyersheim

lectra-t ag, Blegistrasse 13 · CH-6340 Baar

www.brennenstuhl.com

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Brennenstuhl RCS 1000 N - RF Remote Control Switch Set Manual

Advertisement

Need help?

Need help?

Do you have a question about the RCS 1000 N and is the answer not in the manual?

Questions and answers

Table of Contents