Specifications - Mitsubishi Electric MSZ-AP35VGK Operating Instructions Manual

Hide thumbs Also See for MSZ-AP35VGK:
Table of Contents

Advertisement

● OPERATING INSTRUCTIONS ●
S
PECIFICATIONS
Indoor
Model
Outdoor
Function
Power supply
Capacity
Input
Indoor
Weight
Outdoor
Refrigerant fi lling capacity (R32)
Indoor
IP code
Outdoor
LP ps
Permissible excessive
operating pressure
HP ps
Indoor (Super High/
EN
High/Med./Low/Silent)
Noise level (SPL)
Outdoor
Guaranteed operating range
Upper limit
Cooling
Lower limit
Upper limit
Heating
Lower limit
Wi-Fi interface
Model
Input Voltage
Power consumption
Size H×W×D (mm)
Weight (g) (including cable)
Transmitter power level (MAX.)
RF channel
Radio protocol
Encryption
Authentication
Software Version
For Declaration of Conformity, please go to the website below.
http://www.melcloud.com/Support
EN-17
MSZ-AP25VG(K)
MUZ-AP25VG(H)
Cooling
kW
2.5
kW
0.60
kg
kg
kg
MPa
MPa
42/36/30/
dB(A)
24/19
dB(A)
47
Outdoor
Indoor
MUZ-AP25/35/42/50VG MUZ-AP25/35/42/50VGH
32°C DB
46°C DB
23°C WB
21°C DB
-10°C DB
15°C WB
27°C DB
24°C DB
18°C WB
20°C DB
-15°C DB
-16°C WB
MAC-566IFB-E
MAC-577IF2-E
DC12.7 V (from indoor unit)
MAX. 2 W
79×44×18.5
73.5×41.5×18.5
60
17.5 dBm
20 dBm
@IEEE 802.11b
@IEEE 802.11b
1ch ~ 13ch (2412~2472 MHz)
IEEE 802.11b/g/n (20)
AES
WPA2-PSK
XX.00
MSZ-AP35VG(K)
MUZ-AP35VG(H)
Heating
Cooling
Heating
~ /N, 230 V, 50 Hz
3.2
3.5
4.0
0.78
0.99
1.03
31
31
0.55
0.55
45/39/34/
42/36/30/
45/38/31/
24/19
24/19
24/19
48
49
50
46°C DB
-10°C DB
24°C DB
18°C WB
-20°C DB
DB: Dry Bulb
-21°C WB
WB: Wet Bulb
46
MSZ-AP42VG(K)
MUZ-AP42VG(H)
Cooling
Heating
4.2
5.4
1.30
1.49
10.5
35
0.70
IP 20
IP 24
2.77
4.17
42/38/34/
45/40/35/
29/21
29/21
50
51
Note:
Rating condition
Cooling — Indoor:
27°C DB, 19°C WB
Outdoor: 35°C DB
Heating — Indoor:
20°C DB
Outdoor: 7°C DB, 6°C WB
MSZ-AP50VG(K)
MUZ-AP50VG(H)
Cooling
Heating
5.0
5.8
1.55
1.60
40
1.00
44/40/36/
48/43/38/
33/28
33/28
52
52

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents