Table of Contents

Advertisement

Quick Links

Version 8.19
February 2013
JetStor U-Series
Unified Storage
User Manual
JetStor SAS 716U
JetStor SAS 724U
JetStor SAS 716U 10G
JetStor SAS 724U 10G

Advertisement

Table of Contents
loading

Summary of Contents for JetStor U Series

  • Page 1 JetStor U-Series Unified Storage User Manual JetStor SAS 716U JetStor SAS 724U JetStor SAS 716U 10G JetStor SAS 724U 10G Version 8.19 February 2013...
  • Page 2 Trademarks All products and trade names used in this manual are trademarks or registered trademarks of their respective companies. FW versions JetStor U Series: FW 1.1.0 Advanced Computer & Network Corporation 5001 Baum Blvd., Ste 680 Pittsburgh, PA 15213 Tel: 412-683-9010 Fax: 412-683-9070 Email: sales@acnc.com...
  • Page 3: Preface

    Preface About this manual This manual is the introduction of the JetStor Unified Storage systems. It aims to help users easily learn the operation of the disk array system. Information contained in this manual has been reviewed for accuracy, but not for product warranty because of the various environments / OS / settings.
  • Page 4: Conventions

    U Series User Manual CAUTION Cautions indicate that failure to take a specified action could result in damage to the software or hardware. Conventions The following table describes the typographic conventions used in this manual. Conventions Description Bold Indicates text on a window, other than the window title, including menus, menu options, buttons, fields, and labels.
  • Page 5 U Series User Manual UL statement Rack Mount Instructions - The following or similar rack-mount instructions are included with the installation instructions: Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient.
  • Page 6 U Series User Manual CAUTION: Risk of explosion if battery is replaced by incorrect type. Dispose of used batteries according to the instructions. Copyright@1993~2013 Advanced Computer & Network Corp. All Rights Reserved.
  • Page 7: Table Of Contents

    U Series User Manual Contents Chapter 0 PREFACE ............................... 3 ............................3 BOUT THIS MANUAL ............................3 ECHNICAL UPPORT ............................3 IPS AND AUTIONS ..............................4 ONVENTIONS ..........................4 STATEMENTS Chapter 1 OVERVIEW ............................11 ............................11 RODUCT VERVIEW Model Comparison..........................11 Package Contents ..........................
  • Page 8 U Series User Manual ..........................27 ANAGEMENT OFTWARE Download JetCentral ......................... 28 Software Installation and Deployment ..................... 29 ................... 34 SING ENTRAL ERVER IN LIENT ERVER MODE .................... 36 SING ENTRAL LIENT IN LIENT ERVER MODE ....................38 SING ENTRAL...
  • Page 9 U Series User Manual Users ..............................73 Groups ............................... 75 ............................77 UBMENU HARING Explorer ............................. 77 Shares ..............................80 ............................81 UBMENU ERVICES Data Services ............................. 81 CIFS..............................81 NFS ..............................82 AFP ..............................82 FTP ..............................83 WebDAV ............................84 iSCSI ..............................
  • Page 10 U Series User Manual CIFS ........................... 100 INDOWS Method 1: The address input in Explorer ..................100 Method 2: The command line input from Start button ..............101 Method 3: Map a network drive in Explorer ................... 102 ............................103 INUX Redhat Linux 5 ..........................
  • Page 11: Chapter 1 Overview

    U Series User Manual Overview Product Overview This user manual describes how to set up and use the JetStor Unified Storage systems. There are four types of chassis available now. SAS 724U / SAS 724U 10G (4U 24bays) SAS 716U / SAS 716U 10G (3U 16bays)
  • Page 12: Package Contents

    U Series User Manual Host Interface 4U 24 3U 16 6 x GbE iSCSI SAS 724U SAS 716U 2 x 10GbE iSCSI SAS 724U 10G SAS 716U 10G + 2 x GbE iSCSI Package Contents The package contains the following items: JetStor Unified Storage system (x1).
  • Page 13 U Series User Manual This table shows the items located on the LCD Control Module. Number Description LCD display. Up button. Down button. ENT (Enter) button. ESC (Escape) button. MUTE button. Power LED: Green: Power ON.  Off: Power OFF.
  • Page 14: Disk Drive Assembly

    U Series User Manual Disk Drive Assembly Remove a drive tray. Then install a HDD. To install SAS / SATA drives: align the edge of the SAS / SATA drive to the back end of tray; the backplane can directly connect to SAS / SATA drives.
  • Page 15: Rear View

    U Series User Manual Rear View There are two various chassis available now. The following example shows the 724U model. 724U chassis: This table describes the rear modules. Number Description Controller 1 (CTRL 1). Dummy. Power Switch |: ON. ...
  • Page 16 U Series User Manual Below describes the rear panels of 724U and 716U controllers. 724U / 716U (6 x GbE) controller: 724U 10G SFP+ / 716U 10G SFP (2 x 10GbE + 2 x GbE) controller: This table describes the rear components.
  • Page 17 U Series User Manual If the BBM LED stays Off, then the BBM power has run out and it  cannot provide power for the cache anymore. It needs to be recharged or replaced. Management port. Console port. RS 232 port for UPS.
  • Page 18: Raid Concepts

    U Series User Manual RAID Concepts RAID is the abbreviation of Redundant Array of Independent Disks. The basic idea of RAID is to combine multiple drives together to form one large logical drive. This RAID drive obtains performance, capacity and reliability than a single drive. The operating system detects the RAID drive as a single storage device.
  • Page 19: Iscsi Concepts

    U Series User Manual NAS provides both storage and a file system. This is often contrasted with SAN (Storage Area Network), which provides only block-based storage and leaves file system concerns on the "client" side. SAN protocols are SCSI, Fibre Channel, iSCSI, ATA over Ethernet (AoE), or HyperSCSI.
  • Page 20 U Series User Manual Storage protocol, such as iSCSI, has “two ends” in the connection. These ends are initiator and target. In iSCSI, we call them iSCSI initiator and iSCSI target. The iSCSI initiator requests or initiates any iSCSI communication. It requests all SCSI operations like read or write. An initiator is usually located on the host side (either an iSCSI HBA or iSCSI SW initiator).
  • Page 21: Installation

    Installation Overview Before starting, prepare the following items: A management computer with a Gigabit Ethernet NIC (recommend) on the same network as  the JetStor Unified Storage system . Connection cables:  。 All: CAT 5e, or CAT 6 (recommend) network cables.
  • Page 22: System Installation And Deployment

    U Series User Manual 716U / 716U 10G: Slot 1 Slot 5 Slot 9 Slot 13 Slot 2 Slot 6 Slot 10 Slot 14 Slot 3 Slot 7 Slot 11 Slot 15 Slot 4 Slot 8 Slot 12 Slot 16 System Installation and Deployment Using the following instructions to install and deploy the storage system.
  • Page 23 U Series User Manual 724U / 716U: Copyright@1993~2013 Advanced Computer & Network Corp. All Rights Reserved.
  • Page 24 U Series User Manual 724U 10G / 716U 10G: Connect the console cable and UPS as follows.  Using RS-232 cable for UPS (gray color, phone jack to DB9 male) to connect from  controller to APC Smart UPS serial cable (DB9 female side), and then connect the serial cable to APC Smart UPS.
  • Page 25: Power On / Off

    U Series User Manual Attach the power cords and power on the system.  Start the configuration.  Power ON / OFF Power On the System The power switch is located at the rear of the panel. To turn the system ON, press power switch to “|”.
  • Page 26: Chapter 3 Quick Setup

    U Series User Manual Quick Setup Management Interfaces There are several management methods to manage the storage system, described as follows. After booting up the system, the following screen shows management port IP and model name. Take an example of the 724U.
  • Page 27: Web Ui

    Management Software JetStor unified storage management uses JetCentral software. It’s JetStor's overall management software made of all necessary functions to monitor, administer, and configure JetStor's U series systems. JetCentral provides you easy and quick management to all high availability functions and advanced functions and it’s also a highly portable software by using Java-based programming.
  • Page 28: Download Jetcentral

    U Series User Manual Download JetCentral JetStor unified storage provides a web user interface to download JetCentral management software. It supports most common web browsers. Be sure to connect the LAN cable to the management port of the JetStor Unified Storage system.
  • Page 29: Software Installation And Deployment

    There are standalone and client-Server modes in JetCentral software. Standalone mode can access JetStor storage directly. Client-Server mode is centralized management. The access right of client to the storage is controlled by JetCentral Server. If you install the client-server mode, please see the following diagram and deploy.
  • Page 30 U Series User Manual First, install JetCentral software. For the standalone mode, JetCentral can be installed in one host. For the client-server mode, both JetCentral client and server program can be installed in one host or can be divided into several hosts. JetCentral server program is installed in one server, and JetCentral client programs are installed in other hosts.
  • Page 31 U Series User Manual Check the License Agreement, and then click Next button. Select Standalone or Client-Server mode. and then click Next button. If you select Standalone mode, change the location if necessary, and then click Next button. If you select Client-Server mode, please jump to next step.
  • Page 32 U Series User Manual It’s Client-Server mode. Select to install Server or Client Application, or both. Change the location if necessary, otherwise click Next button. Click Install button. Copyright@1993~2013 Advanced Computer & Network Corp. All Rights Reserved.
  • Page 33 U Series User Manual Done, click Finish button. The JetCentral software contains the following items: JetCentral Server: It’s a Windows based program. (It’s available in Client-Server mode.)  JetCentral Client: It’s a Java based program. JRE (Java Runtime Environment) is required. JRE ...
  • Page 34: Using Jetcentral Server In Client-Server Mode

    All Programs -> JETSTOR -> JetCentral -> JetCentral Server. There are two tabs in the main page. The following describes the functions: System: it displays a list of JetStor products in the network environment. And Login  operation to every JetStor storage.
  • Page 35 U Series User Manual Take an example of getting the authorization to a system. Select a group name. Click Access button. It will pop up a window. Multi-select the systems to be controlled by the group member. And then click OK button.
  • Page 36: Using Jetcentral Client In Client-Server Mode

    This section describes the main page of the JetCentral client. It’s a Java based program. JRE (Java Runtime Environment) is required. Run the program in Start -> All Programs -> JETSTOR -> JetCentral -> JetCentral Client. It will display a dialog box for authentication. Enter the JetCentral server IP address, account and password which are created in JetCentral server.
  • Page 37 U Series User Manual Menu Function Icon Operation Options Tabs Indicators and Icons Managed Product Area Operation Area Event Log Area The following describes the main page: Menu: JetCentral client drop-down menu options.  Function Icon: QSnap, VD Clone and QReplica function icons. If the icon is grayed, the ...
  • Page 38: Using Jetcentral Client In Standalone Mode

    Using JetCentral Client in Standalone mode It’s the same as above. Run the program in Start -> All Programs -> JETSTOR -> JetCentral -> JetCentral Client. The main page of the JetCentral client is displayed. It will scan all JetStor storages in the same LAN segment and display in “Managed Product Area”.
  • Page 39 U Series User Manual Indicators and Icons There are up to six indicators at the top-right corner. In Configuration tab, a chassis graphic is displayed below. Move the cursor over the graphics. A mouse-over tip will pop up to briefly describe each part the cursor is pointed at.
  • Page 40: Quick Setup Via Wizard

    U Series User Manual Intuitive Graph The following describes the main page: Menu: JetCentral client drop-down menu options.  Function Icon: Qsnap, VD Clone and QReplica function icons. If the icon is grayed, the  function is disabled. Managed Product Area: This area lists all system names and IP addresses which are ...
  • Page 41 U Series User Manual Setup the system time and NTP (Network Time Protocol) server. When it is done, click Next button. Setup a pool. Select a RAID level from the drop-down list. Click Next button. The wizard will automatically provide a list of valid RAID levels for users to choose according to how many free disks are available.
  • Page 42 U Series User Manual At the confirmation message, click Finish button. After completion, it will create a pool which includes two file systems and one volume. The Public folder shares CIFS, NFS, AFP, FTP data services. And the volume attaches a LUN for iSCSI usage.
  • Page 43 U Series User Manual Copyright@1993~2013 Advanced Computer & Network Corp. All Rights Reserved.
  • Page 44: Chapter 4 Basic Configuration

    U Series User Manual Basic Configuration Interface Hierarchy This table describes the hierarchy of the JetCentral client. Menu Bar L2, Button or Menu File Download MIB file Save / Cancel Download system Save / Cancel information Exit Exit JetCentral program...
  • Page 45: Operation Tab: Summary

    U Series User Manual Change UPS property. View/Summary Overview Service status / Pool status / Controller information Utilization CPU loading / Memory usage / Management / LAN View/Event Event log Save as / Clear all Options: Clear event log Maintenance...
  • Page 46: Utilization

    U Series User Manual This table describes the indicators and icons. Icon Description RAID indicator:  Green: All RAID groups are functioning. Red: A RAID group is degraded or has failed.  Temperature indicator: Green: Temperature is normal.  Red: Temperature is too high.
  • Page 47: Menu: File

    U Series User Manual Menu: File The menu File is for accessing the Download MIB file, Dump to USB and Exit option. Download MIB file The Download MIB file provides to download MIB file for SNMP usage. Download system information The Download system information will download a compressed file to your local drive.
  • Page 48: Submenu: System

    U Series User Manual Submenu: System The menu Configuration -> System is for accessing the System setting and Network setting options. System Setting The menu Configuration -> System -> System setting or System setting tab of the operation area is for accessing the System, Date and Time, Mail setting, Messenger, SNMP, System Log Server and Event Log Filter option tabs.
  • Page 49: Date And Time

    U Series User Manual System name: To change the System name, highlight the old name and type in a new one.  System indication: Enable it to turn on the system LED for locating this system in the racks. ...
  • Page 50: Messenger

    U Series User Manual You can also select which levels of event logs which you would like to receive. The default setting only includes WARNING and ERROR event logs. When it is done, click OK button. Messenger The Messenger icon is used to set up pop-up messages via Windows messenger (not MSN).
  • Page 51: Snmp

    U Series User Manual SNMP The SNMP icon is used to setup SNMP traps (for alerting via SNMP). The options available in this dialog: SNMP: It allows up to three SNMP trap addresses. The default community setting is public. ...
  • Page 52: Event Log Filter

    U Series User Manual 。 WinSyslog: http://www.winsyslog.com/ 。 Kiwi Syslog Daemon: http://www.kiwisyslog.com/ Most UNIX systems have built-in syslog daemon. When it is done, click OK button. Event Log Filter The Event Log Filter tab is used to setup event log filter.
  • Page 53 U Series User Manual We define that the management port is a special network port. It can download JetCentral software via HTTP, but it cannot be used as WebDAV service nor linked aggregation with other LAN ports. In addition, GbE and 10GbE LAN ports cannot link aggregation each other either. The following table describes the relationship with the service and the network ports.
  • Page 54 U Series User Manual DNS: If necessary, the IP address of DNS server can be entered or changed here. The DNS  settings will be applied to all network ports, which means you ONLY need to select one of the network ports and start DNS setting.
  • Page 55 U Series User Manual 。 Trunking: Configures multiple network ports in parallel to increase the link speed beyond the limits of any single port. 。 LACP: It is part of IEEE specification 802.3ad that allows several physical ports to be bundled together to form a single logical channel.
  • Page 56: Submenu: Storage

    U Series User Manual Become default gateway: The default gateway can be changed by clicking Become default  gateway. There can be only one default gateway. To remove the default gateway, right click to bring out the menu and select Disable default gateway.
  • Page 57 U Series User Manual the pool is not ready for use yet. Health The health of the hard drive: Good: the hard drive is good.  Failed: the hard drive is failed.  Error alert: S.M.A.R.T. error alert.  ...
  • Page 58: Pool

    U Series User Manual failure gives users precautions to back up hard drive or replace the hard drive. This is much better than the hard drive crashing when it is writing data or rebuilding a failed hard drive. The numbers displayed are real-time value. The number in parenthesis is the threshold value. The threshold values from different hard drive vendors are different;...
  • Page 59 U Series User Manual Expand: Add more RAID sets to the same pool to expand the capacity.  Set home directory: Assign home directory to the pool. (This option is only visible when  home directory is not assigned.) Add disks -> Read cache: Assign SSD drives as SSD read cache to the pool.
  • Page 60 U Series User Manual 5. Optionally, configure the following: Write Cache: It’s to enable or disable the write cache option of hard drives. The  default value is Disabled. Standby: It’s to enable or disable the auto spindown function of hard drives, ...
  • Page 61 U Series User Manual Here to use “Expand”? 1. First, Pool 1 is created with one RAID set, which is configured as RAID 0 with 2 disks. 2. We need to expand the capacity of Pool 1 by adding another RAID set – a RAID 5 with 4 disks.
  • Page 62 1. Make sure you have added proper SSD drives to the system. In the Vendor field, only SSD drive with coded “JetStor” string can be used as SSD cache. 2. Go to Add disks -> Read cache. Select the SSD drive(s) you want to use for read cache.
  • Page 63: Zfs

    TIP: Only SSD drives can be used as SSD cache, which includes read cache (L2ARC) and write cache (ZIL, ZFS Intent Log). Starting from FW1.0.3, only SSD drives that are shipped by JetStor can be used as SSD cache. This is to ensure the upmost compatibility and performance improvement.
  • Page 64 U Series User Manual This table shows the column descriptions. Column Name Description Name The name of the file system or volume. Type File system or volume. Quota (GB) The Quota of the file system or volume. Reserved (GB) Reserved capacity of the file system or volume.
  • Page 65: Enterprise Features - Deduplication

    U Series User Manual Use the drop-down list to select a Pool. Select Type, Property and No. of data copies. Enter the Size for the file system or volume. Click OK button. TIP: “Type” has two options – “File system” and “Volume”.
  • Page 66 Deduplication size limit can be removed by the following means :  。 Per pool basis. Add read cache (L2ARC) using SSD drives provided by JetStor Technology. 。 Per system basis. Add more memory to the system or delete deduplicated data to release space.
  • Page 67: Enterprise Features - Compression

    U Series User Manual With a dedup ratio of 3, it means there are about 3 copies of identical data. Data size without dedup will take up 22692MB (22GB). Enterprise features – Compression Compression algorithm adopts LZJB.  Applied to both file system and volume.
  • Page 68 U Series User Manual 3. Copy several bitmap files that are over the size of 20MB. 4. Check the network drive property again. The actual space taken is less than 20MB, which means Compression is functioning. Copyright@1993~2013 Advanced Computer & Network Corp. All Rights Reserved.
  • Page 69: Enterprise Features - Thin Provisioning

    U Series User Manual Enterprise features – Thin provisioning Dynamic allocating space to store user data.  Applied to both file system and volume.  Remove stranded or reserved-but-unused capacity. Improve storage efficiency.  How to use thin provisioning? 1. Create a filesystem with thin provisioning turned ON. The Size option will be grey out.
  • Page 70 U Series User Manual 2. Check the network drive property. The size is the remaining pool size. So it’s dynamic. 3. Copy some files to the share. There is no pre-allocated space (reserved size). The used size reflects just the exact amount of the files being copied.
  • Page 71: Snapshot

    U Series User Manual Snapshot The menu Configuration -> Storage -> Snapshot or Configuration -> Snapshot tab of the operation area provides functions to manage snapshot activities such as take snapshot, rollback, clone, delete, or view the status of the snapshots.
  • Page 72: Lun

    U Series User Manual Use the drop-down list to select a ZFS name. Enter a Snapshot name for the snapshot. Click OK button. The menu Configuration -> Storage -> LUN or Configuration -> LUN tab of the operation area provides functions to manage iSCSI volumes such as attach, detach or view the status of logical unit numbers for each volume.
  • Page 73: Submenu: Account

    U Series User Manual Select the volume from the drop-down list. Enter an iSCSI node name for access control, or fill-in wildcard (*) for access by all hosts. Select the Target number from the drop-down list. Select the LUN number from the drop-down list.
  • Page 74 U Series User Manual This table shows the column descriptions. Column Name Description User name The account name. Group The user belongs to the groups. Quota (GB) User quota space. Used (%) The percentage of the quota usage. Email User’s email.
  • Page 75: Groups

    U Series User Manual Enter the Username, Password, and Retype password. The other fields are optional. Click OK button to create an account. TIP: The password is required to be at least 12 and up to 16 alphanumeric characters. This is because of UnifiedAUTH mechanism that will integrate with iSCSI CHAP account.
  • Page 76 U Series User Manual #User The number of users that belong to this group. Description Group’s description. Functions in the right click menu: Add: Create a group.  Delete: Delete the group.  Edit: Edit the group.  Take an example of creating a group.
  • Page 77: Submenu: Sharing

    U Series User Manual Submenu: Sharing The menu Configuration -> Sharing is for accessing the Explorer and Shares options. Explorer The menu Configuration -> Sharing -> Explorer or Sharing -> Explorer tab of the operation area provides to create file system/volume, edit file system/volume, delete file system/volume, create folder for file system, take snapshot, auto snapshot, add share for file system, attach LUN for volume or browse the whole storage pool structure.
  • Page 78 U Series User Manual Auto snapshot: Set auto snapshot on the volume.  Attach LUN: Attach LUN to the volume.  Detach LUN: Detach LUN from the volume.  Take an example of creating a file system or a volume.
  • Page 79 U Series User Manual Click Select user(s) and group(s) to share the folder to designated users and groups. Check one or more data services that you want to apply to the folder. Please click Settings button of each data service for more details.
  • Page 80: Shares

    4. Domain: If you want to allow all the computers in a certain network domain to have access to the share. Use this option. For example, JetStor.com, ee.standford.edu, or web.cern.ch. 5. Everyone: Allow access to computers from all kinds of IP addresses.
  • Page 81: Submenu: Services

    The CIFS (Common Internet File System) tab is used to setup CIFS protocol. The CIFS is a network protocol that offers file services for Windows computers. JetStor unified storage provides CIFS capability without the need for a Windows server in the network. Starting this service will open the...
  • Page 82: Nfs

    The NFS (Network File System) tab is used to setup NFS protocol. NFS is a protocol for sharing files and directories on a network among Linux machines and Unix machines. Starting this service will open the following ports on the JetStor Unified Storage system: TCP 111 (rpcbind) ...
  • Page 83: Ftp

    U Series User Manual The FTP(File Transfer Protocol) tab is used to setup FTP protocol. JetStor unified storage allows you to configure the FTP server so that users can browse and download data using their web browser or FTP client software. FTP is easy to use and it is cross-platform. All major operating systems have FTP client function.
  • Page 84: Webdav

    The WebDAV(Web Distributed Authoring and Versioning) tab is used to setup WebDAV protocol. It is an extension of HTTP v1.1 protocol that allows users to manage files across different operating system platforms. Starting this service will open the following ports on the JetStor Unified Storage system: TCP 80 (httpd) ...
  • Page 85: Connection

    U Series User Manual When it is done, click OK button. Connection The Connection tab is used to display the connections of the data services.  This table shows the column descriptions on File service. Column Name Description Protocol Data service protocol.
  • Page 86: Directory Services

    The others are Active Directory for Windows and LDAP services. JetStor UnifiedAUTH mechanism is the backbone of all the directory services. It simplifies the use of all the data services (CIFS, NFS, AFP, FTP, WebDAV, iSCSI) and frees the users from memorizing different account/password sets for different data services.
  • Page 87 And then it will synchronize with the server automatically. Or you may set the duration in minutes for how often the JetStor U Series should synchronize with the AD server. TIP: In order to make sure you can successfully login Active Directory server, please make sure the following two requirements are met.
  • Page 88 U Series User Manual LDAP  LDAP (Light-weighted Directory Access Protocol) service supports LDAP version3 to manage the accounts. The maximum number of LDAP users and groups is 65536. Enter the settings of LDAP above. When it is done, click OK button. If the information is correct, the accounts will be added to Account ->...
  • Page 89: Backup

    U Series User Manual Backup The menu Configuration -> Services -> Backup or Backup tab of the operation area provides functions to set up the backup services. Currently, it supports Amazon S3 and Replication services. Both Amazon S3 and replication services are applied to the whole file system or volume, which is the right next level to the storage pool.
  • Page 90: Replication

    The Replication tab is used to setup the replication service. It support local cloning and  remote replication to other JetStor Unified Storage arrays. There is no limit to the number of how many local cloning and remote replication tasks can ...
  • Page 91 U Series User Manual Take an example of adding a task. Click Add by clicking mouse right button. Enter the Task name, and select a file system or volume to replicate. Then click Next button. Select the Local cloning or Remote replication. Remote replication needs to enter the target IP, username and password.
  • Page 92: Antivirus

    1. Users try to write a file into JetStor Unified Storage. 2. JetStor Unified Storage sends the file through ICAP to antivirus server for scanning. 3. Antivirus server scans the file, repairs it if it is infected, and returns the clean file to the JetStor Unified Storage.
  • Page 93 U Series User Manual checks; it is well-suited for use with unified storage appliance and file sharing services. The purpose is real-time monitoring all incoming files (writes) for continuous protection. The actions taken when virus is spotted are determined by ICAP server. The infected files are displayed in Report tab.
  • Page 94: Report

    U Series User Manual Enter the settings of AntiVirus server IP. The default port number o ICAP is 1344. The other fields are optional. Add the exclude file type and shares if needed. When it is done, click OK button.
  • Page 95: Ups

    U Series User Manual The menu Configuration -> Enclosure -> UPS or clicking UPS tab of the operation area is used to set up a UPS (Uninterruptible Power Supply). Currently, the system only supports and communicates with Smart-UPS series by APC (American Power Conversion Corp, http://www.apc.com/) and Magatec UPS.
  • Page 96: Menu: View

    U Series User Manual Batteries failed. Please change them NOW!  Battery level (%) Current power percentage of battery level. The system will shut down when either Shutdown battery level (%) or Shutdown delay (s) reaches the condition. User should set these values carefully.
  • Page 97: Menu: Maintenance

    U Series User Manual The event log is displayed in reverse order which means the latest event log is on the first / top page. Menu: Maintenance The menu Maintenance is for accessing the Upgrade firmware, Reset to factory default, Reboot and shutdown and Authentication options.
  • Page 98: Reset To Factory Default

    U Series User Manual Reset to Factory Default The menu Maintenance -> Reset to factory default allows users to reset the system configurations back to the factory default settings. The default values are: Admin password: 00000000  IP address: DHCP ...
  • Page 99: Authentication

    U Series User Manual Authentication The menu Maintenance -> Authentication is used to authenticate the system. If the password of the system is changed, the authentication is needed. Menu: Help The menu Help is for accessing the About option. Copyright@1993~2013 Advanced Computer & Network Corp. All Rights Reserved.
  • Page 100: Chapter 5 Access Shares From Your Operating System

    Access Shares from Your Operating System Introduction There are 5 data services provided by JetStor Unified Storage. This chapter will show you how to access shares from different operating systems. We will introduce CIFS/Samba, NFS, FTP, AFP, and WebDAV. Before you can access the shares, please make sure that you have enable file sharing services and related settings in Submenu: Sharing of Chapter 4.
  • Page 101: Method 2: The Command Line Input From Start Button

    U Series User Manual Windows will pop up a dialog requesting for account and password. Please put in your account and password. When the authentication is clear, the share is ready for you to use as follows: Method 2: The command line input from Start button Click Start button to bring up the start menu.
  • Page 102: Method 3: Map A Network Drive In Explorer

    Method 3: Map a network drive in Explorer Please follow the steps below to map a network share from JetStor Unified Storage to a drive letter. The network share will be automatically mapped the next time you boot your Windows.
  • Page 103: Nfs And Linux

    NFS and Linux JetStor Unified Storage supports NFS version 3 and version 4. If version 4 connections cannot be established, the system will automatically try to establish the connection using version 3 protocols. Before using the NFS shares, please make sure the NFS settings of the shares are properly configured.
  • Page 104: Redhat Linux 6

    -F nfs -o rw 192.168.8.180:/SQL_DB2 /mnt/nas NFS and vShpere5 If you want to use JetStor U Series as vSphere 5 storage through NFS connection, please make sure you export the NFS share with read/write access rights. In the vSphere 5 UI setting for NFS share, please use the following syntax as shown in the screenshot below.
  • Page 105: Afp And Ac Os X

    U Series User Manual IP address of NAS NFS share name AFP and Mac OS X In Finder, go to “Go” and select “Connect to Server”. Put in the network port IP address that you want to access. Click “Connect”.
  • Page 106: Ftp

    U Series User Manual A window with all accessible shares for AFP protocol will pop up for you to select the share you want to connect to. Click “Ok”. There you go. The share is ready for you to access.
  • Page 107: Method 2: Using Ftp Client Application

    U Series User Manual Method 2: Using FTP client application There are a lot of FTP client tools in Windows platform such as WSFTP, FileZilla. In Linux X-Window environment, there are gFTP, WXftp, and LLNL XFTP. For example, using FileZilla in Windows looks like the screenshot below.
  • Page 108: Webdav

    U Series User Manual WebDAV JetStor Unified Storage WebDAV service supports the following operating systems : 32bit Windows : Windows XP SP2, Windows 7 SP1, Windows Server 2008 SP1  64bit Windows operating systems have issues to support WebDAV service. We recommend ...
  • Page 109 U Series User Manual From the Computer icon on Desktop, right click on Computer icon and select Map Network Drive. When the wizard appears, click Connect to a Web site that you can use to store your documents and pictures.
  • Page 110 U Series User Manual Follow the instructions and click Next. Select Choose a custom network location and click Next. Copyright@1993~2013 Advanced Computer & Network Corp. All Rights Reserved.
  • Page 111 U Series User Manual In Internet or network address input, put in the WebDAV share in the following syntax. http://<IP address>: 50000/<WebDAV share> Please make sure you put in the port number 50000. Put in the required account and password information. You may name the network location. Here we simply use the default as 192.168.122.112.
  • Page 112: Method 2: Using 3 Rd Party Webdav Client Application

    U Series User Manual Method 2: Using 3 party WebDAV client application Recommended tools include WebDrive, NetDrive, or Bitkinex. Copyright@1993~2013 Advanced Computer & Network Corp. All Rights Reserved.
  • Page 113: Chapter 6 Software Application

    U Series User Manual Software Application Microsoft iSCSI initiator Here are the step by step instructions of how to setup Microsoft iSCSI Initiator. Please visit Microsoft website for latest iSCSI initiator. This example is based on Microsoft Windows Server 2008 R2.
  • Page 114: Setup Mpio

    U Series User Manual It can connect to an iSCSI disk now. Setup MPIO If running MPIO, please continue. Click Discovery tab to connect the second path. Click Discover Portal button. Enter the IP address or DNS name of the target.
  • Page 115 U Series User Manual Click OK button. Click Targets tab, select the second path, and then click Connect button. Enable multi-path checkbox. Then click OK button. Copyright@1993~2013 Advanced Computer & Network Corp. All Rights Reserved.
  • Page 116: Setup Mc/S

    U Series User Manual Done, it can connect to an iSCSI disk with MPIO. Setup MC/S If running MC/S, please continue. Select one target name, click Properties button. Click MCS button to add additional connections. Click Add button. Click Advanced button.
  • Page 117: Disconnect

    U Series User Manual Select Initiator IP and Target portal IP, and then click OK button. Click Connect button. Click OK button. Done. Disconnect Select the target name, click Disconnect button, and then click Yes button. Copyright@1993~2013 Advanced Computer & Network Corp. All Rights Reserved.
  • Page 118 U Series User Manual Done, the iSCSI device disconnect successfully. Copyright@1993~2013 Advanced Computer & Network Corp. All Rights Reserved.
  • Page 119: Glossary And Acronym List

    U Series User Manual Glossary and Acronym List Common Terminology Item Description RAID Redundant Array of Independent Disks. There are different RAID levels with different degree of data protection, data availability, and performance to host environment. The Physical Disk belongs to the member disk of one specific RAID group.
  • Page 120 U Series User Manual ports. iSNS Internet Storage Name Service. Copyright@1993~2013 Advanced Computer & Network Corp. All Rights Reserved.
  • Page 121: Index

    U Series User Manual Index Delete File System ............84 Delete Volume ..............84 Detach LUN ..............84 Edit file system ..............84 AFP ..................89 Edit Share ................ 84 Change ................89 Edit Volume ..............84 Amazon S3 ................96 Remove Share ..............
  • Page 122 U Series User Manual Users............... 80 Enclosure ..............101 Hardware monitor ..........102 JetCentral Client ..............39 UPS ..............102 Event Log Area............43, 46 Services............... 88 Function Icon ............. 43, 46 AntiVirus ..............99 Indication and Icons............43 Backup ..............96 Intuitive Graph..............
  • Page 123 U Series User Manual Wizard ................. 46 VLAN ID ................62 Auto snapshot ..............70 Create ................70 Web Distributed Authoring and Versioning ......91 Delete ................70 Web UI (Web User Interface) ..........33 Edit .................. 70 WebDAV ................91 Take snapshot ..............

This manual is also suitable for:

Sas 716uSas 724uSas 716u 10gSas 724u 10g

Table of Contents