DSP configuration of your controller, you can obtain a fresh default file from SEEBURG acoustic line and re-install the original factory pre- sets yourself. Efficient and intelligent limiter functions provide optimal protection without sacrificing any of the potential of the system.
G Sub 1802 dp 3 Safety instructions Safety instructions Acoustic Even a low input level can result in a sound pressure level at the loudspeaker which can be damaging to your hearing. Do not remain in close proximity to the loudspeaker when it is being operated. Use hearing protection.
Page 5
G Sub 1802 dp 3 Safety instructions If the loudspeaker is connected to a power source in which the volt- age is too high, a protective mechanism is triggered which reliably safeguards the amplifier module and DSP. Once triggered, the pro- tection must be renewed by a qualified service technician.
G Sub 1802 dp 4 Connectors/Indicators 4.2 Connectors XLR connectors (1) The G Sub 1802 dp should be connected with a standard symmetrically wired XLR cable. To con- nect the input signal to further devices, use the male XLR Loop thru connector. To obtain full power performance from the system, the signal source should be able to provide a minimum of 6 dBu distortion free output voltage.
G Sub 1802 dp 4 Connectors/Indicators 4.3 Controls Mode button: Switch between the modes Status / Level and Presets. Set button: Set various values and Mute on/off. 4.4 Status indication Mute LED: Lights red when the system is muted (press the Set button in Status Mode), or in technically critical conditions.
G Sub 1802 dp 5 Operating Operating 5.1 Starting up When the system is switched on, it retains the settings from the previous usage. This also applies to the Bank selection. The system is then in the Status Mode. If the red Mute LED is lit as a result of the previous setting, no signal will be passed.
G Sub 1802 dp 5 Operating 5.3 Setting level After switching on and starting up, the G Sub 1802 dp is in Status Mode. Pressing the Mode button once selects the Level Mode, in which you can adjust the output volume in 3 dB steps. Seven different values between +6 dB and -12 dB are available, with 0 dB being the standard setting.
G Sub 1802 dp 5 Operating 5.4 Recalling presets After switching on and starting up, the A2 dp is in Status Mode. Pressing the Mode button twice to selects the Preset Mode. Three different presets can be called up using the set button. The green LED above on the right indicates that you are in Preset Mode.
G Sub 1802 dp 5 Operating cardioid. The cardioid function works regardless of the choice of three possible presets. More details in section 5.7. 5.4.2 Preset Bank 2 – Hypercardioid LP 80: Preset for use with a mid-high system (e.g. Galeo C, X8 or A8). The acoustical cut-off frequency in this preset is 80 Hz.
3. Make sure your computer's volume is set to 100%. 4. Load the ".wav" file received from SEEBURG acoustic line into a music player. 5. Press the play button. 6. After a successful programming operation, the Mute LED turns off.
G Sub 1802 dp 5 Operating 5.7 Cardioid Mode The Cardioid Mode serves to generate a cardioid response pattern for the subwoofers. Using this mode, a significant reduction in bass energy emission to the rear of the system can be achieved. A minimum of 2 subwoofer units is required.
Page 15
G Sub 1802 dp 5 Operating Installation using three subwoofers (recommended): The performance of the cardioid configuration is better when 3 subwoofers are used together. The units can be stacked on top of each other or laid side by side on the ground. If in a stack, the low- est unit should face the rear.
58,0 x 116,0 x 78,0 cm Size height x width x depth Order No. 00640/dp The technical data sheet and further information about possible applications for the system and available accessories can be downloaded at the following Internet address: https://www.seeburg.net/download_getfile.php?file=downloads/06-Datenblaetter/G-Subwoofer/G- Sub-1802-dp_Datenblatt_dt.pdf...
DIN EN 60065 DIN EN 55103-1:1996, classes E1 to E4 DIN EN 55103-2:1996, classes E1 to E4 Declared by: Winfried Seeburg, SEEBURG acoustic line GmbH Place and date: Senden, 01.10.2019 Legally binding sign: ____________________________________________ The attachments constitute part of this declaration. This declaration certifies conformity with the listed guidelines, but does not guarantee any product characteristics.
Page 18
Benutzerhandbuch / User Manual Irrtum bei Beschreibung sowie technische Änderungen vorbehalten. Alle SEEBURG acoustic line Produkte sind nur für den gewerblichen Einsatz bestimmt. All specifications are current at the time of publishing but are subject to change. SEEBURG acoustic line...
Need help?
Do you have a question about the Acoustic G Sub 1802 dp and is the answer not in the manual?