Hide thumbs Also See for G Sub 1001 dp+:

Advertisement

Quick Links

Benutzerhandbuch
G Sub 1001 dp+
Version 3.3
07.04.2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G Sub 1001 dp+ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Seeburg G Sub 1001 dp+

  • Page 1 Benutzerhandbuch G Sub 1001 dp+ Version 3.3 07.04.2020...
  • Page 2: Table Of Contents

    G Sub 1001 dp+ 1 Contents Contents Contents .......................... 2 Foreword .......................... 3 Safety instructions ......................4 Connectors/Indicators ....................6 Connection panel ........................6 Connectors ..........................7 Controls ........................... 9 Status indication ........................9 Operation ........................10 Starting up..........................10 Selecting a bank ........................
  • Page 3: Foreword

    DSP configuration of your controller, you can obtain a fresh default file from SEEBURG acoustic line and re-install the original factory pre- sets yourself. Efficient and intelligent limiter functions provide optimal protection without sacrificing any of the potential of the system.
  • Page 4: Safety Instructions

    G Sub 1001 dp+ 3 Safety instructions Safety instructions Acoustic Even a low input level can result in a sound pressure level at the loudspeaker which can be damaging to your hearing. Do not remain in close proximity to the loudspeaker when it is being operated. Use hearing protection.
  • Page 5 G Sub 1001 dp+ 3 Safety instructions If the loudspeaker is connected to a power source in which the volt- age is too high, a protective mechanism is triggered which reliably safeguards the amplifier module and DSP. Once triggered, the pro- tection must be renewed by a qualified service technician.
  • Page 6: Connectors/Indicators

    G Sub 1001 dp+ 4 Connectors/Indicators Connectors/Indicators 4.1 Connection panel XLR connectors (1) SpeakON black (5) PowerCon grey (3) PowerCon blue (2) SpeakON black (4)
  • Page 7: Connectors

    G Sub 1001 dp+ 4 Connectors/Indicators 4.2 Connectors XLR connectors (1) The G Sub 1001 dp+ should be connected with a standard symmetrically wired XLR cable. To connect the input signal to further devices, use the male XLR Loop thru connector. To obtain full power performance from the system, the signal source should be able to provide a minimum of 6 dBu distortion free output voltage.
  • Page 8 G Sub 1001 dp+ 4 Connectors/Indicators SpeakON black (5) This connector is used to connect additional passive loudspeakers to the second amplifier channel. Presets are available for selection for various high-mid systems (e. g. i4, L16, TS Nano or TSM8) or two additional G Sub 1001 units (switch to Bi-Amp mode).
  • Page 9: Controls

    G Sub 1001 dp+ 4 Connectors/Indicators 4.3 Controls Mode button: Switch between the modes Status / Level and Presets. Set button: Set various values and Mute on/off. 4.4 Status indication Mute LED: Lights red when the system is muted (press the Set button in Status Mode ), or in technically critical conditions.
  • Page 10: Operation

    G Sub 1001 dp+ 5 Operation Operation 5.1 Starting up When the system is switched on, it retains the settings from the previous usage. This also applies to the Bank selection. The system is then in the Status Mode . If the red Mute LED is lit as a result of the previous setting, no signal will be passed.
  • Page 11: Setting Level

    G Sub 1001 dp+ 5 Operation 5.3 Setting level Pressing the Mode button once selects the Level Mode, in which you can adjust the output volume in 3 dB steps. There are four settings available: +3 dB, 0 dB (standard), -3 dB and -6 dB. The setting is done by pressing the Set button.
  • Page 12: Preset Bank 2 - L-Series

    G Sub 1001 dp+ 5 Operation Cardioid Mode: The so-called backward attenuation of a subwoofer system (combina- tion of at least 2x subwoofers) can be significantly increased with a cardioid. The cardioid function works regardless of the choice of three possible presets.
  • Page 13: Reprogramming Of Dp-Speakers With Preset Audio Files

    DSP controller can only receive data in the muted state. 3. Make sure your computer's volume is set to 100%. 4. Load the ".wav" file received from SEEBURG acoustic line into a music player. 5. Press the play button. 6. After a successful programming operation, the Mute LED turns off.
  • Page 14: Cardioid Mode

    G Sub 1001 dp+ 5 Operation 5.7 Cardioid Mode The Cardioid Mode serves to generate a cardioid response pattern for the subwoofers. Using this mode, a significant reduction in bass energy emission to the rear of the system can be achieved. A minimum of 2 subwoofer units is required.
  • Page 15 G Sub 1001 dp+ 5 Operation Installation using three subwoofers (recommended): The performance of the cardioid configuration is better when 3 subwoofers are used together. The units can be stacked on top of each other or laid side by side on the ground. If in a stack, the low- est unit should face the rear.
  • Page 16: Technical Specifications

    28,0 x 43,0 x 43,0 cm height x width x depth Order No. 00605/dp+ The technical data sheet and further information about possible applications for the system and available accessories can be downloaded at the following Internet address: http://www.seeburg.net/download_getfile.php?file=downloads/06-Datenblaetter/G-Subwoofer/G- Sub-1001-dp-plus_Datenblatt_dt.pdf...
  • Page 17: Declaration Of Conformity

     DIN EN 60065  DIN EN 55103-1:1996, classes E1 to E4  DIN EN 55103-2:1996, classes E1 to E4 Declared by: Winfried Seeburg, SEEBURG acoustic line GmbH Place and date: Senden, 01.01.2010 Legally binding sign: ____________________________________________ The attachments constitute part of this declaration. This declaration certifies conformity with the listed guidelines, but does not guarantee any product characteristics.

Table of Contents