I N S T A L LA T I O N M A N U A L Contents 1. Introduction 2. CE declaration 3. SAFETY 3.1 General 3.2 Regulations 3.3 Precautions/safety instructions during installation 3.4 Second thermocouple safety 3.5 Oxypilot safety 4.
Please, read and use this installation manual carefully and completely, prior to installing this appliance. If you use the DRU Powervent system® or the DRU Smartvent system®, you must carefully and fully read and use the accompanying installation manual as well, prior to its installation.
CE label, and make sure there is sufficient ventilation of the room where the appliance is installed, according to legislation. Ø If you are installing an appliance with a closed combustion: only use the concentric systems supplied by DRU. Ø If you are installing a free-standing appliance: •...
Check whether the appliance is suitable for the type of gas and the gas pressure used at the location. !Caution 5.1.1 Reconstruction to different type of gas If you want to convert this appliance into a different type of gas, please contact DRU's service department and ask what is possible. Reconstructions should only be performed by authorized gas installers.
5.4 Placing a built in appliance (if applicable) Not all DRU built in appliances are supplied with a control hatch. If not included in the delivery, this control hatch is available separately. In case of appliances with closed combustion (type C11/C31) we always recommend using the Dru control hatch.
Placing the control hatch section 5.6; • the Dru control hatch is not supplied with all appliances. Nevertheless, we recommend only using a Dru control hatch, if available, exept in the case of B appliances.
A number of components are placed in the control hatch, such as data plate, gas control, receiver belonging to the ® remote control and, if applicable, the components belonging to the DRU Powervent system Place the control hatch as follows; see Appendix 3, fig. 3 for details: Ø...
(see section 5.8.4). • Only use the concentric system supplied by DRU This system has been tested in combination with the !Caution appliance. DRU cannot guarantee a proper and safe operation of other systems and does not accept any responsibility or liability for this;...
I N S T A L LA T I O N M A N U A L The concentric system with wall or roof terminal has to comply with the following conditions: • In appendix 2, table 4 or 5 you can find whether a concentric pipe should be connected and what the minimum vertical length would have to be.
The surrounding space is used to supply combustion air. The following requirements apply when connecting to an existing chimney: • only allowed when used in combination with the special DRU chimney kit. The installation regulation is also supplied; •...
I N S T A LL A T I O N M A N U A L 5.9 Additional instructions !Tip It will be easier to reach the gas control, if you remove the front panel 5.9.1 Placing the appliance When placing the appliance, please take the following aspects into account: Ø...
IN S T A LLA TION M A NU A L 5.10 Glass pane • Avoid damaging the pane during removal/placing; !Caution • Avoid/remove fingerprints on the glass pane, as they will burn into the glass. 5.10.1 Removing the glass pane When removing the front glass pane, you should follow the next steps: Ø...
I N S T A LL A T I O N M A N U A L 5.11.2 Restrictor slide The restrictor slide (R) is supplied separately (see Appendix 3, Fig. 14). It is mounted as follows: Ø Remove the glass pane as described in section 5.10.1; Ø...
Place the receiver in its intended holder under the appliance or in the control hatch according to Appendix 3, fig. 39. • If you want to use an adapter, only an adapter supplied by DRU will guarantee a proper operation of the receiver. 6.1.1 Placing / replacing the receiver's batteries Follow the procedure below when placing the batteries: Ø...
(e.g. Domotics). For this purpose, there are 4 connection points at the side of the receiver (see Appendix 3, fig. 44). For connecting an external control unit, you will need a “Domotics connection cable for GV60”. Consult DRU's service website. The following contacts are possible: •...
IN S T A LLA TION M A NU A L 7.3 Ignition pilot and main burner For igniting the pilot and main burner, see the User Manual, chapter 4, section 4.2, Remote control. 7.3.1 First ignition of the appliance after installation or adjustments !Caution After installation, or after work has been performed, you should ignite the appliance for the first time without the glass window.
I N S T A LL A T I O N M A N U A L 8. Maintenance The appliance must be inspected once per year by a skilled installer in the field of gas-fired heating, and repaired if necessary. Check at least whether the appliance is working properly and safely.
IN S T A LLA TION M A NU A L 9. Delivery You must explain to the user how to operate the appliance. You must give him/her instructions on putting it in operation, the safety measures, the operation of the remote control and annual maintenance (see the User Manual).
I N S T A L LA T I ON M A N U A L Appendix 1 diagnosis of malfunctions Fires with electronic ignition, fault finding: Ignition and burning Start 2.10 Do(es) main burner(s) 2.06 Pilot can be lit. 2.08 Does main burner ignite smoothly and across 2.01 Can pilot be lit? Does it stay alight?
Page 21
Flames: too high Voltage 0 mV - proper flue terminal used, make - Line pressure. - 2nd couple defective. should be 'DRU'; - Burner pressure. - Cross ligting main burner very slow. - terminal correctly sited on roof or Take actions "Cross lighting too wall relative to obstructions;...
Page 22
I N S T A LL A T I O N M A N U A L Malfunction search diagram atmospheric gas-fired heating appliance with electronic ignition: Starting up cycle. Start 1.05 1.01 Does receiver beep? 1.03 Short sound signals, 1 sec after One long 5 second beep, (possibly each other, followed by the preceded by 7 short beeps).
IN S T A LLA TION M A NU A L Appendix 2 Tables Table 1: Parts included with the delivery Part Number Wood set Installation manual User manual Decoration ring Restrictor slide Hexagonal nut M5 Washer 8.4 mm Sealing cap Socket spanner 8 mm Remote control with receiver 9V block battery Penlite battery (AA type)
Page 24
2E+3P 2H3P 2EK3P Concentric appliance connection 150/100 Applicable concentric systems DRU LAS ES-E 200/150/100, DRU LAS ES-I 150/100, DRU LAS AG-I 150/100 Flame protection version Pilot flame with thermocouple 2nd thermocouple safety Atmosphere safety Explosion hatch Ventilation hole chimney breast...
Page 25
IN S T A LLA TION M A NU A L Table 3: Line-pressure when using G31 Country mbar NL / DK / FI / NO / SE / HU / BA / GR FR / BE / IT / PT / ES / GB / IE Permissibility and conditions concentric system with wall terminal ...
Page 26
I N S T A L LA T I ON M A N U A L Table 5: Determining permissibility concentric system G20/G25/ Total number of meters Total no. of meters vertical and/or sloping pipe length G25.3/G31 horiz. pipe length no bends 2 bends 3 bends...
IN S T A LLA TION M A NU A L Appendix 3 Figures 442,5 38C-1776 38c-1777 /1 Min 40 mm 1x90° Min 500 mm 38C-744q 45° 0 - 3m 1x90° 38C-2307 /1 38C-744F...
Page 28
I N S T A LL A T I O N M A N U A L 38c-1779 38c-1778 38c-1780/1...
Page 29
IN S T A LLA TION M A NU A L 38c-1781/1 38c-1782 38c-1783...
Page 30
I N S T A LL A T I O N M A N U A L 38c-1784 38c-1785...
Page 31
IN S T A LLA TION M A NU A L 38c-1786 38c-1787...
Page 32
I N S T A LL A T I O N M A N U A L 38P-0265 38P-0266 38p-0022 38p-0023 3 8 P - 0 1 1 3 38P-0273...
Page 33
IN S T A LLA TION M A NU A L 38P-0267/0 38P-0268 38P-0269...
Page 34
I N S T A LL A T I O N M A N U A L 38P-0270 38P-0271...
Page 35
IN S T A LLA TION M A NU A L 38p-0181 38p-0179 SECTION A-A SCALE 1 : 20 38p-0182 38C-1663/0...
Page 36
DRU Verwarming B.V. The Netherlands Postbus 1021, NL-6920 BA Duiven Ratio 8, NL-6921 RW Duiven EN ...
Need help?
Do you have a question about the Circo RCE G20 and is the answer not in the manual?
Questions and answers