Battery Guard Waterproof BGW-200
OWNERS MANUAL
DESCRIPTION
The Battery Guard Waterproof BGW-200
(hereafter referred to as the BGW) is an intelligent,
user-programmable, fully waterproof battery guard.
The BGW has additional options for a remote off
switch and an alarm output for connecting a buzzer,
LED strip or relay. To ensure low losses, the BGW is
provided with two threaded rod and nut connections;
input+ and output+. The other connections (Minus-,
Remote Off-, Config-input and Status/alarm output)
are connected via 6.3 mm faston connectors.
The BGW is equipped with a bright status LED
displaying the different functional stages. The BGW
features an "automatic board system detection",
this enables to automatically detect if the BGW is
connected to a 12 V or a 24 V system.
INSTALLATION
Install the BGW on a cooling (metal) surface allowing
to dissipate the heat generated. Use a maximum
cable length of 50 cm between the battery and the
BGW will ensure accurate monitoring the battery
voltage.
Please note!
• The product may only be installed by qualified
electricians who are fully aware of the require-
ments for working with high battery voltages.
• The use of poor/ bad connection material and/or
wires that are too thin can damage the BGW.
• A short circuit between the battery's positive and
negative terminals can cause serious damage to
the system.
• Always use fuses of the correct value.
• Use a 1.5 mm
2
with a 5A fuse for the BGW-200
from the battery (-) to the BGW for the negative (–)
connection.
Use this connection only for the BGW!
WIRING DIAGRAM (please see last page)
EN
OPERATION
Input voltage protection
The input voltage protection values (undervoltage
threshold, undervoltage reset, overvoltage threshold
and overvoltage reset) can be set by the user.
Please see "CONFIGURE/Programming" how to
set these values.
Undervoltage
If the BGW's input voltage drops below the
undervoltage threshold for 15 seconds, the status/
alarm output will turn on. The LED will also indicate
undervoltage. The BGW will shut down one minute
later and the alarm output and LED will turn off.
When the BGW's input voltage exceeds the reset
threshold for 5 seconds, the BGW will turn back
on, and the LED will indicate that the BGW is active
again.
Overvoltage
The BGW will shut down if the input voltage exceeds
the overvoltage threshold for 0.5 seconds.
The status/alarm output and LED will flash/switch
with a frequency of 1 Hz.
Overcurrent protection
The current through the BGW is constantly monitored.
If an excessive current flows through the BGW for
too long, the BGW will shut down to prevent damage
to both the BGW and the connected equipment.
The BGW will turn on again after 1 minute.
Temperature protection
The BGW will shut down immediately if its
temperature exceeds 85 °C. The LED will indicate
a fault. The BGW will turn on again after 1 minute if
the temperature has dropped below 75 °C.
Ground Loss protection
The BGW will shut down if it detects that the minus
(–) is disconnected on the supply (battery) side.

Advertisement

Table of Contents
loading

Summary of Contents for Samlexpower BGW-200

  • Page 1 • Always use fuses of the correct value. Temperature protection • Use a 1.5 mm with a 5A fuse for the BGW-200 The BGW will shut down immediately if its from the battery (-) to the BGW for the negative (–) temperature exceeds 85 °C.
  • Page 2: Programming Table

    The LED will indicate a fault. The BGW will turn on The user can briefly (short) make the connection again after 1 minute. again to select programme position #2, etc., etc.. Remote off If no connection is made for approx. 4 seconds, A switch can be installed between the OFF input and the LED will display the set state again.
  • Page 3: Schéma Des Connexions

    • Utilisez un câble de 1,5 mm avec un fusible 5A Protection contre la surchauffe pour le BGW-200 de la batterie (-) au BGW pour la Le BGW s’éteint immédiatement lorsque sa connexion négative (–). Utilisez cette connexion température dépasse 85 °C. La LED indique qu’il uniquement pour le BGW ! y a un «...
  • Page 4 Protection contre la perte de la masse La LED s’allume en retour. À ce moment, la position Le BGW s’éteint dès qu’il détecte que la borne de programmation n° 1 est sélectionnée. négative (–) a été déconnectée côté alimentation. Lorsque l’utilisateur établit à nouveau brièvement le La LED indique qu’il y a un «...
  • Page 5: Manual Del Propietario

    MANUAL DEL PROPIETARIO DESCRIPCIÓN FUNCIONAMIENTO Protección de la tensión entrada El protector de batería a prueba de agua BGW-200 (en lo sucesivo, BGW) es un protector de batería El usuario puede configurar los valores de la inteligente, programable por el usuario y protección de la tensión de entrada, umbral de...
  • Page 6 Control de pérdida de suelo A fin de ajustar el número de posición correcto, Tan pronto como el BGW detecte que en el lateral deberá cortarse de nuevo la misma conexión; el de alimentación el min (–) está suelto, el BGW se LED se encenderá...
  • Page 7: Technical Data

    TECHNICAL DATA BGW-200 ELECTRICAL Input voltage range 6 … 35 V Maximum continuous output current (@25 °C) 200 A Peak current (@25 °C) 1200 A (±0.7 sec) Voltage drop 50 mV @ 200 A Current Output active 3.2 mA Consumption Output inactive 3.2 mA...
  • Page 8 112.5 x 76 mm FUSE BATTERY REMOTE OFF CONFIG Battery Guard Owner's Please read this manual BEFORE Manual operating the Models: units. BGW-40 BGW-60 Battery Guard Owner's Please read this manual BEFORE Manual operating the Models: units. BGW-200 samlexamerica.com 11004-BGW-40-60-1222 11004-BGW-200-xx23...