INSTALLATION
STEP 2 & 3 CONNECT TO THE ELEC-
TRICITY SUPPLY
We recommend that the appliance is
connected by a competent person who
is a member of a "Competent Person
Scheme" & who will comply with the
I.E.E. & local regulations.
Important: Ensure that you route all
mains electrical cables well clear of any
adjacent heat source, such as an oven or
grill.
Warning: This appliance must be earthed.
For 70/90cm appliances:
1. The appliance must be installed using
a double pole control unit of 32 ampere
minimum capacity separation at all poles.
2. Access to the mains terminal is gained
by opening the terminal block cover at
the rear of the appliance (use a small flat
bladed screwdriver).
3. Connection should be made with
suitable twin & earth flexible cable,
minimum 4mm² , which is suitable for use
up to 25 amps.
4. First strip the wires, then push the
cable through the cable clamp in the
terminal block cover.
5. Connect the cable to the terminal block
& tighten the cable clamp screw.
6. Close the terminal box, ensuring that
the cover is engaged on the locking tabs.