8-3. INSTRUCTION OF TROUBLESHOOTING
Start
Indoor unit oper-
ates.
Outdoor unit
does not operate.
Outdoor unit
Outdoor unit
operates only
does not
in Test Run
operate even
operation.
in Test Run
operation.
Check room
Refer to "How
temperature
to check
thermistor.
inverter/com-
Refer to 8-7.
pressor".
"Test point
diagram and
voltage".
Left lamp
Flash on
and OFF at
0.5-second
intervals
Cause:
Indoor/Outdoor
unit
• Miswiring or
trouble of
serial signal
Refer to 8-6.
"How to
check mis-
wiring and
serial signal
error".
Indoor unit operates.
Outdoor unit does
not operate normally.
Indoor unit
Unit does not
operates, when
operate nor-
EMERGENCY
mal operation
OPERATION
in COOL or
switch is pressed.
HEAT mode.
Refer to
Refer to 8-6.
"Check of R.V.
"Check of remote
coil".
controller and
receiver P.C.
board".
Left lamp
Left lamp
2-time ash
3-time ash
Cause:
Cause:
Indoor unit
Indoor unit
• Trouble
• Trouble of
of room
indoor fan
temperature
motor
/ indoor coil
thermistor
Check room
Refer to 8-6.
temperature
"Check of
thermistor
indoor fan
and indoor
motor".
coil thermis-
tor. Refer
to 8-7."Test
point diagram
and voltage".
Indoor unit does
OPERATION INDICATOR
not receive the
lamp on the indoor unit is
signal from re-
ashing ON and OFF.
mote controller.
Indoor unit does
not operate, when
EMERGENCY
OPERATION
switch is pressed.
1. Check indoor/out-
door connecting wire.
(Check if the power is
supplied to the indoor
unit.)
2. Refer to 8-6.
"Check
of indoor electronic
control P.C. board and
indoor fan motor".
Left lamp
Left lamp
4-time ash
5-time ash
Cause:
Cause:
Indoor unit
Outdoor unit
• Trouble
• Outdoor
of indoor
power
unit control
system
system
abnormality
Replace the
Refer to
indoor elec-
"How to
tronic control
check
P.C. board.
inverter/com-
pressor".
15
If blinking of OPERATION INDI-
CATOR lamp cannot be checked,
it can be checked with failure
mode recall function.
"Test Run operation" means
the operation within 30 minutes
after EMERGENCY OPERA-
TION switch is pressed.
Refer to outdoor unit service manual.
Left lamp
Left lamp
7-time ash
6-time ash
Cause:
Cause:
Outdoor unit
Outdoor unit
• Trouble of
• Trouble of
thermistor in
outdoor con-
outdoor unit
trol system
Refer to
Replace the
"Check of
inverter P.C.
outdoor ther-
board or
mistors".
the outdoor
electronic
control P.C.
board.
Left lamp
14-time ash
Cause:
Outdoor unit
• Other ab-
normality
Check "Flow
chart of the
detailed
outdoor unit
failure mode
recall func-
tion."