FIAMA F1X5 SSI Series Use And Maintenance Manual

FIAMA F1X5 SSI Series Use And Maintenance Manual

Display unit with microprocessor

Advertisement

Quick Links

F1X5_SSI
Display unit with microprocessor
USE AND MAINTENANCE MANUAL
MICROPROCESSOR-BASED DISPLAY UNIT WITH
SSI F1X5_SSI INPUT
Pag. 1/1
Date:13/01/16
F1X_SSI_ing.doc

Advertisement

loading

Summary of Contents for FIAMA F1X5 SSI Series

  • Page 1 F1X5_SSI Display unit with microprocessor USE AND MAINTENANCE MANUAL MICROPROCESSOR-BASED DISPLAY UNIT WITH SSI F1X5_SSI INPUT Pag. 1/1 Date:13/01/16 F1X_SSI_ing.doc...
  • Page 2: Environmental Conditions

    Do not use solvents derived from hydrocarbons (trichloroethylene, gasoline, diluents etc.). The use of these products will irreversibly compromise the functioning of the instrument. Repairs must be carried out exclusively at a FIAMA technical assistance centre.
  • Page 3: Installation

    F1X5_SSI Display unit with microprocessor • The stated instructions in this manual do not substitute, but complement the obligations of the legislation in force regarding safety regulations. Description The F1X5_SS instrument is six-digit display unit (reading scale –99999 , +999999) with an input from transducers that use the SSI interface (encoder, optical lines, position transducers, pressure transducers, etc.).
  • Page 4 F1X5_SSI Display unit with microprocessor h) The instrument contains components sensitive to electrostatic charge, therefore the handling of the electronic cards in it must be carried out with the appropriate devices, with the aim of avoiding permanent damage to the very components. Power supply a) Before connecting the instrument verify that the power voltage is within the permitted limits indicated on the plate.
  • Page 5: Reset / Enter

    F1X5_SSI Display unit with microprocessor PROGRAMMING The keys used for programming are the following: To start programming To increase the digit undergoing modification, To select the constant to be modified To move from one digit to the next one, To exit the constant setting mode To confirm the entered values RESET/ENTER Push...
  • Page 6 F1X5_SSI Display unit with microprocessor It defines the format of data of the SSI interface: if 0, the format is binary; if 1 the format is Gray. This parameter shall be set in line with what is requested by the transducer connected to the display unit. Reset mode Setting of the reset mode allows for the selection of the instrument behaviour when the key is...
  • Page 7 F1X5_SSI Display unit with microprocessor Number of bits of the SSI interface Number of bits of the SSI protocol to be set in line with the value requested by the transducer connected to the F1X5_SSI display unit. Such value can range between 4 and 24. Default value: 24.
  • Page 8 Phone (+39) 0521.672.341 - Fax. (+39) 0521.672.537 - e.mail: info@fiama.it - www.fiama.it FIAMA srl will not be held responsible for damage to people or property resulting from tampering with and misuse or use non-complying with the characteristics of the instrument.

This manual is also suitable for:

F1x502ssiF1x512ssiF1x522ssiF1x532ssi