Summary of Contents for Amit ALP2200/A
Page 1
ALP2200/A ALP2200/A130 Information LED panel for rolling stock Operation manual Version 1.00 alp2200ax_g_en_100...
Page 2
ALP2200/A ALP2200/A130 AMiT, spol. s r.o. does not provide any warranty concerning the contents of this publication and reserves the right to change the documentation without obliga- tion to inform anyone or any authority about it. This document can be copied and redistributed under following conditions: 1.
ALP2200/A ALP2200/A130 History of revisions Document name: alp2200ax_g_en_100.pdf Author: Ondřej Rott Revision Date Changes 13. 8. 2015 New document Related documentation Application Note AP0016 ̶ Principles of using RS485 interface file: ap0016_en_xx.pdf alp2200ax_g_en_100 4/21...
1. Introduction ALP1120/A and ALP2200/A130 are outdoor information LED panel intended to be built-in to rolling stock. Difference between LED panels ALP2200/A and ALP2200/A130 is only in cable length. Information panels are designed and approved in accordance with EN 50155:2007 standard.
ALP2200/A ALP2200/A130 2. Technical parameters (1072 × 184) mm Viewing zone Viewing area (135 × 24) pixels Resolution LED grid 8 mm LED colour Yellow, 590 nm typ. Luminance Typically 800 cd/m 120 ° *) Viewing angle Note *) Luminance drop to 50 % at viewing angle border.
Page 7
ALP2200/A ALP2200/A130 Unit overall mass of plastics Dangerous ALP2200/A 2750 g materials ALP2200/A130 2800 g Included mass of self- extinguishing plastics ALP2200/A 2750 g ALP2200/A130 2800 g Device does not contain PUR, PVC, Asbestos Device conforms 2011/65/EU (ROHS) 1907/2006EU (REACH)
X2-ID X1-PWR X2-ID GND-RS GND-RS Fig. 3 - Recommended drawing symbol for ALP2200/A, ALP2200/A130 2.3. Temperature dependence Information panel is equipped with internal temperature sensor; depending on measured temperature is controlled the maximum brightness according to following table. Internal temperature Function -40 °C to 45 °C...
ALP2200/A ALP2200/A130 3. Conformity assessment The equipment meets the claims of Czech government decree NV616/2006; the compliance assessment has been performed in accordance with harmonized standard EN 50121-3-2:2006 in obligatory scope given by EN 50155:2007. Tested in accordance Type of test...
ALP2200/A ALP2200/A130 3.1. Other tests This product was assessed and approved for use in railway applications according to standards: Tested in accordance Type of test Classificati with standard Railway applications – Electronic EN 50155:2007 Complies equipment used on rolling stock.
ALP2200/A ALP2200/A130 4. Power supply Information LED panels ALP2200/A, ALP2200/A130 can be supplied only with DC supply voltage. Supply voltage is connected to X1 connector with 6 pins; connector is common also for RS485 interface. Connector Signal Signal description Supplying...
ALP2200/A ALP2200/A130 5. Communication lines and peripherals 5.1. RS485 Information LED panels ALP2200/A, ALP2200/A130 contains single galvanic separated interface RS485. RS 485 line is connected to 6-pin connector X1, which is also common for panel powering. RS485 Connector Signal Signal description...
ALP2200/A ALP2200/A130 More information about using the RS485 line can be found in Application Note AP0016. The RS485 line communication protocol is determined by user appli- cation in processor. 5.1.1 RS485 line termination For correct function, RS485 line must be terminated with terminating resistors.
AP0016. The RS485 line communication protocol is determined by user application in processor. 5.2. Geographic addressing Information panel ALP2200/A, ALP2200/A130 geographic address is set by interconnecting the address inputs ADx with COM pin on connector X2. Combination of bits AD1 (LSB) to AD4 (MSB) represents by itself the binary form of geographic address.
ALP2200/A ALP2200/A130 Table of Logical levels Address addresses Examples Leaving the X2 connector unwired causes that address is set to 64. By connecting COM, AD2 and AD3 pins is the address set to 70. 5.3. Light sensor Information panel is equipped with light sensor, that is used for measuring of ambient light.
ALP2200/A ALP2200/A130 6. Connectors and terminals layout Information panels ALP2200/A, ALP2200/A130 contain two WAGO connectors. WAGO231-636/019-000 connector is used for panel powering and communica- tion via RS485. Its counterpart is WAGO231-306/102-000. WAGO231-635/019-000 connector is used for geographic addressing. Its coun- terpart is WAGO231-305/102-000.
ALP2200/A ALP2200/A130 7. Mounting Information panel is designed to be mounted onto rail coach interior using mounting holes located on the panel sides. Information panel is attached by bolts, fastened to 4 nuts with M6 thread. Fig. 15 - Location of mounting holes 7.1.
ALP2200/A ALP2200/A130 8. Ordering information and completion Unit complete – see chapter 8.1 Completion Information ALP2200/A panel Unit complete – see chapter 8.1 Completion ALP2200/A130 8.1. Completion ALP2200/A, Part Quantity ALP2200/A130 Information LED panel WAGO 231-306/102-000 X1 connector counterpart WAGO 231-305/102-000 X2 connector counterpart...
ALP2200/A ALP2200/A130 9. Maintenance Cleaning Depending on equipment usage, the dust is to be removed occasionally from equipment. The equipment can be cleaned by dry soft brush or vacuum cleaner, only when turned-off and disassembled. Cleaning of front polycarbonate should be made by dry or moisten cloth and such cleaning agents which does not cause scratching of viewing surface.
ALP2200/A ALP2200/A130 10. Waste disposal Electronics The disposal of electronics is subject to the regulations on handling electrical disposal waste. The equipment must not be disposed of in common public waste. It must be delivered to places specified for that purpose and recycled.
Need help?
Do you have a question about the ALP2200/A and is the answer not in the manual?
Questions and answers