How to proceed if a repair is necessary ................24 Dismount..........................26 Dismounting steps......................26 Disposal ......................... 26 Supplement ..........................27 Technical data ........................ 27 Dimensions ........................30 Industrial property rights ....................32 Trademark ........................32 925-0375 VR-90 • Vibrating Rod...
Page 3
Contents Safety instructions for Ex areas Take note of the Ex specific safety instructions for Ex applications. These instructions are attached as documents to each instrument with Ex approval and are part of the operating instructions. Editing status: 2018-11-22 925-0375 VR-90 • Vibrating Rod...
Action This arrow indicates a single action. Sequence of actions Numbers set in front indicate successive steps in a procedure. Battery disposal This symbol indicates special information about the disposal of bat- teries and accumulators. 925-0375 VR-90 • Vibrating Rod...
During work on and with the device, the required personal protective equipment must always be worn. Appropriate use The VR-90 is a sensor for point level detection. You can find detailed information about the area of application in chapter "Product description". Operational reliability is ensured only if the instrument is properly used according to the specifications in the operating instructions manual as well as possible supplementary instructions.
You can find the EU conformity declaration on our website under www.vega.com/downloads. SIL conformity VR-90 meets the requirements of functional safety according to IEC 61508. Further information is available in the Safety Manual "VEGAVIB series 60". Installation and operation in the USA and Canada This information is only valid for USA and Canada. Hence the follow- ing text is only available in the English language.
Principle of operation Application area VR-90 is a point level sensor with vibrating rod for point level detection. It is designed for industrial use in all areas of process technology and is preferably used for bulk solids.
Solid detection in water If VR-90 was ordered for solid detection in water, the vibrating rod is calibrated to the density of water. If covered by water (density: 1 g/ cm³/0.036 lbs/in) VR-90 signals "uncovered". Only if the vibrating element is also covered with solids (e.g.
Page 9
Technical data - Ambient conditions" • Relative humidity 20 … 85 % Lifting and carrying With instrument weights of more than 18 kg (39.68 lbs) suitable and approved equipment must be used for lifting and carrying. 925-0375 VR-90 • Vibrating Rod...
DIN/EN/IEC/ANSI/ISA/UL/CSA 61010-1. Switching point In general, VR-90 can be installed in any position. The instrument only has to be mounted in such a way that the vibrating element is at the height of the desired switching point.
Mounting instructions Mounting socket The vibrating element should protrude into the vessel to avoid buildup. For that reason, avoid using mounting bosses for flanges and screwed fittings. This applies particularly to use with adhesive products. Filling opening Mount the instrument in such a way that the vibrating rod does not protrude directly into the filling stream. 925-0375 VR-90 • Vibrating Rod...
Page 12
The vibrating rod must be mounted in a way that takes the arrange- ment of the filling and emptying apertures into account. To compensate measurement errors caused by the material cone in cylindrical vessels, the sensor must be mounted at a distance of d/6 from the vessel wall. 925-0375 VR-90 • Vibrating Rod...
Page 13
4 Mounting Fig. 4: Filling and emptying centred Fig. 5: Filling in the centre, emptying laterally VR-90 Discharge opening Filling opening Horizontal mounting To achieve a very precise s witching point, you can install VR-90 horizontally. However, if the switching point can have a tolerance of a 925-0375 VR-90 • Vibrating Rod...
Page 14
4 Mounting few centimeters, we recommend mounting VR-90 approx. 20° inclined to the vessel bottom to avoid buildup. 20° Fig. 6: Horizontal mounting Inflowing medium If VR-90 is mounted in the filling stream, unwanted false measurement signals can be generated. For this reason, mount VR-90 at a position in the vessel where no disturbances, e.g. from filling openings, agitators, etc., can occur.
In hazardous areas, use only approved cable connections for VR-90. Take note of the corresponding installation regulations for Ex applica- tions. Connection cable for Ex applications Cover all housing openings conforming to standard according to EN 60079-1. 925-0375 VR-90 • Vibrating Rod...
10. If necessary, carry out a fresh adjustment 11. Screw the housing lid back on The electrical connection is finished. Wiring plan, single chamber housing The following illustrations apply to the non-Ex as well as to the Ex-d version. 925-0375 VR-90 • Vibrating Rod...
Page 17
Stainless steel, electropolished (not with Ex d) Filter element for pressure compensation (not with Ex d) Wiring plan We recommend connecting VR-90 in such a way that the switching circuit is open when there is a level signal, line break or failure (safe state).
Page 18
5 Connecting to power supply Fig. 10: Wiring plan Shielding 925-0375 VR-90 • Vibrating Rod...
Note: As a rule, always set the mode with mode switch (2) before starting the setup of VR-90. The switching output will change if you set the mode switch (2) afterwards. This could possibly trigger other connected instruments or devices.
6 Setup VR-90 will be more sensitive and light solids can be detected more reliably. For instruments detecting solids in water, these settings are not applicable. The density range is preset and must not be changed. Mode adjustment (2) With the mode adjustment (min./max.) you can change the switching condition of the output.
Page 21
6 Setup Level Switching status Control lamp Fault Switch open flashes red 925-0375 VR-90 • Vibrating Rod...
These may be caused by the following, e.g.: • Sensor • Process • Voltage supply • Signal processing The first measure to take is to check the output signal. In many cases, Fault rectification the causes can be determined this way and the faults quickly rectified. 24 hour service hotline Should these measures not be successful, please call BinMaster service at +1 402-434-9102. 925-0375 VR-90 • Vibrating Rod...
Proceed as follows: 1. Switch off voltage supply 2. Unscrew the housing lid 3. Lift the opening levers of the terminals with a screwdriver 4. Pull the connection cables out of the terminals 5. Loosen the two screws with a screw driver (Torx size T10 or slot 925-0375 VR-90 • Vibrating Rod...
14. Check cable gland on tightness. The seal ring must completely encircle the cable. 15. Screw the housing lid back on The electronics exchange is now finished. How to proceed if a repair is necessary You can find an RMA return form as well as detailed information about the procedure in the support area of our website: www.binmaster.com. 925-0375 VR-90 • Vibrating Rod...
Page 25
If a repair is necessary, please proceed as follows: • Print and fill out one form per instrument • Clean the instrument and pack it damage-proof • Attach the completed form and, if need be, also a safety data sheet outside on the packaging 925-0375 VR-90 • Vibrating Rod...
Pass the instrument directly on to a specialised recycling company and do not use the municipal collecting points. If you have no way to dispose of the old instrument properly, please contact us concerning return and disposal. 925-0375 VR-90 • Vibrating Rod...
Page 28
(176°F) 40°C (104°F) 0°C (32°F) -50°C 50°C 100°C 150°C 200°C 250°C (-58°F) (122°F) (212°F) (302°F) (392°F) (482°F) -40°C (-40°F) Fig. 30: Ambient temperature - Process temperature Process temperature Ambient temperature Temperature range with temperature adapter 925-0375 VR-90 • Vibrating Rod...
Page 29
They are part of the delivery or can be downloaded under www.vega.com, "Instrument search (serial number)" as well as in the general download area. Max. 20 mm (0.8 in) with product density < 0.03 g/cm³ (0.0011 lbs/in³). 925-0375 VR-90 • Vibrating Rod...
Fig. 31: Housing versions Plastic single chamber Stainless steel single chamber (electropolished) Stainless steel single chamber (precision casting) Aluminium - single chamber ø 29 mm (1.14") ø16 mm (0.63") Fig. 32: VR-90, threaded version G1 (DIN ISO 228/1) 925-0375 VR-90 • Vibrating Rod...
Page 31
9 Supplement G1½ ø 29 mm (1.14") ø16 mm (0.63") Fig. 33: VR-90, threaded version G1½ (DIN ISO 228/1) ø 34 mm (1.34") Fig. 34: Temperature adapter 925-0375 VR-90 • Vibrating Rod...
Industrial property rights VEGA product lines are global protected by industrial property rights. Further information see www.vega.com. Trademark All the brands as well as trade and company names used are property of their lawful proprietor/originator. 925-0375 VR-90 • Vibrating Rod...