WIKORA WBO 506 UNO Installation Manual Operating Instructions

WIKORA WBO 506 UNO Installation Manual Operating Instructions

Dhw storage tank

Advertisement

Quick Links

Installation manual
Operating instructions
Index
1
General ................................................................................................................................................................................... 2
2
Transport and installation ....................................................................................................................................................... 2
3
Dimensions and connections .................................................................................................................................................. 3
4
Technical data ........................................................................................................................................................................ 4
5
Installation .............................................................................................................................................................................. 5
6
Commissioning ....................................................................................................................................................................... 6
7
Maintenance and wear parts .................................................................................................................................................. 6
8
Recycling and disposal ........................................................................................................................................................... 6
9
Warranties and guarantee ...................................................................................................................................................... 7
10
Installation record ................................................................................................................................................................... 8
© Wikora GmbH
DHW storage tank
WBO 506 UNO/DUO/H/WPSOL
Installation
and
undertaken by a specialist.
General terms and conditions of warranty state that
all installations must be carried out by a suitably
trained and qualified plumber who observes the
local norms and regulations.
The installation and maintenance record must
be entirely completed and the user has to be
instructed accordingly.
Efficient operation can only be guaranteed if the
instructions of this manual are followed.
Warranty does not cover any damage caused due
to non-observance of this manual and the technical
rules in force.
The system is to be checked annually by a
specialized company. In addition, occurring defects
must be repaired immediately.
This document should be handed over to the
client on completion of the installation.
.
Page 1
WIKORA GmbH
89568 Hermaringen
Phone: (07322) 9605-0
Fax: (07322) 9605-30
email: contact@wikora.de
commissioning
must
As of 2/1/2019
Errors excepted.
Friedrichstr. 9
be

Advertisement

Table of Contents
loading

Summary of Contents for WIKORA WBO 506 UNO

  • Page 1: Table Of Contents

    Phone: (07322) 9605-0 Fax: (07322) 9605-30 email: contact@wikora.de Installation manual DHW storage tank Operating instructions WBO 506 UNO/DUO/H/WPSOL Installation commissioning must undertaken by a specialist. General terms and conditions of warranty state that all installations must be carried out by a suitably trained and qualified plumber who observes the local norms and regulations.
  • Page 2: General

    The sleeves IG ½ "for venting and emptying must be sealed with suitable plugs or venting / draining valves. Please remove the existing protective caps and replace them with these plug or vent / drain valves. © Wikora GmbH Page 2 As of 2/1/2019 Errors excepted.
  • Page 3: Dimensions And Connections

    ∅ D Type [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] WBO 506 UNO 1680 2055 1958 WBO 506 DUO 1680 2055 1680 1010 1958 WBO 506 H50 1680 2055 1098 1164 1958 WBO 506 H60...
  • Page 4: Technical Data

    Standing loss [Watt] Willingness to heat Kwh/ 24h 1,88 1,96 1,88 1,88 1,96 Energyefficiency class ca. 254 ca. 254 Weight (empty) [kg] ca. 182 ca. 206 ca. 243 Chart 3 © Wikora GmbH Page 4 As of 2/1/2019 Errors excepted.
  • Page 5: Installation

    Max. heating performance up to 200 l NW 15 (1/2“) 75 kW above 200 to 1000 l NW 20 (3/4“) 150 kW Illustration 3 (Schematic drawing– example hydraulic system heating) © Wikora GmbH Page 5 As of 2/1/2019 Errors excepted.
  • Page 6: Commissioning

    8 Recycling and disposal The products are specified and manufactured according to VDI 2243. The products are mechanically separable and 100% recyclable. Make sure that the components are disposed according to the relevant regulations. © Wikora GmbH Page 6 As of 2/1/2019...
  • Page 7: Warranties And Guarantee

    Compliance with the limits of the valid DHW regulations(TrinkwV 2001), especially the limits in accordance with Appendix 2, Part 1-2 and Appendix 3 Coverage EU : Compliance with the limits of the EG-Regulations 83/98 * Start of guarantee at date of invoice © Wikora GmbH Page 7 As of 2/1/2019 Errors excepted.
  • Page 8: Installation Record

    In the case of reclamation, the receipts for maintenance must be provided as proof. Please complete the data sheet, including the reason for reclamation, and submit to Wikora. Submitting the maintenance record does not ensure any promise of guarantee or claim.

This manual is also suitable for:

Wbo 506 duoWbo 506 h60Wbo 506 wpsol

Table of Contents