WIKORA WBO 2005 UNO Installation Manual Operating Instructions

WIKORA WBO 2005 UNO Installation Manual Operating Instructions

Dhw storage tank

Advertisement

Quick Links

Installation manual
Operating instructions
Index
1
General ................................................................................................................................................................................... 2
2
Transport and installation ....................................................................................................................................................... 2
3
Dimensions and connections .................................................................................................................................................. 3
4
Technical data ........................................................................................................................................................................ 4
5
Installation .............................................................................................................................................................................. 4
6
Commissioning ....................................................................................................................................................................... 6
7
Maintenance and wear parts .................................................................................................................................................. 6
8
Recycling and disposal ........................................................................................................................................................... 6
9
Warranties and guarantee ...................................................................................................................................................... 7
10
Installation record ................................................................................................................................................................... 8
© Wikora GmbH
DHW storage tank
WBO 2005/3005 UNO/DUO
Installation
and
undertaken by a specialist.
General terms and conditions of warranty state that
all installations must be carried out by a suitably
trained and qualified plumber who observes the
local norms and regulations.
The installation and maintenance record must
be entirely completed and the user has to be
instructed accordingly.
Efficient operation can only be guaranteed if the
instructions of this manual are followed.
Warranty does not cover any damage caused due
to non-observance of this manual and the technical
rules in force.
The system is to be checked annually by a
specialized company. In addition, occurring defects
must be repaired immediately.
This document should be handed over to the
client on completion of the installation.
.
Page 1
WIKORA GmbH
Friedrichstr. 9
89568 Hermaringen
Phone: (07322) 9605-0
Fax: (07322) 9605-30
email: contact@wikora.de
commissioning
must
As of January 31, 2019
Errors excepted.
be

Advertisement

Table of Contents
loading

Summary of Contents for WIKORA WBO 2005 UNO

  • Page 1: Table Of Contents

    Technical data ..................................4 Installation ....................................4 Commissioning ..................................6 Maintenance and wear parts ..............................6 Recycling and disposal ................................6 Warranties and guarantee ..............................7 Installation record ................................... 8 © Wikora GmbH Page 1 As of January 31, 2019 Errors excepted.
  • Page 2: General

    1 General Depending on the type and design, WIKORA tanks are suitable for heating and / or storing DHW and / or heating water. The heating is achieved indirectly via heat generators, if applicable, from different heat sources. The maximum working pressure and working temperature can be found in the technical data.
  • Page 3: Dimensions And Connections

    3 Dimensions and connections Illustration 1 Dimensions: Type ∅ d [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] WBO 2005 UNO 1200 1440 1625 1345 2090 1088 1150 2237 WBO 2005 DUO 1200 1440...
  • Page 4: Technical Data

    4 Technical data Description WBO 2005 UNO WBO 2005 DUO WBO 3005 UNO WBO 3005 DUO Storage volume (real) acc. to DIN EN 12897 [litre] 2002 1998 2938 2894 Max. working temperature DHW / Heating [°C] 95/110 95/110/110 95/110 95/110/110 Max.
  • Page 5 If the control lamp is not illuminated, check the connections and contacts. Attention ! There is no warranty claim in case of unconnected or inaccurately connected external current anodes. © Wikora GmbH Page 5 As of January 31, 2019 Errors excepted.
  • Page 6: Commissioning

    It should be examined for the first time after 2 years and afterwards annually in order to check its transmission. The diameter should be at least 1/3 of the original diameter, the surface should be homogenous and without any limescale crust. If necessary, it should be replaced by an original Wikora anode to protect the tank against corrosion.
  • Page 7: Warranties And Guarantee

    Under condition that the limits of the valid DHW regulations have been respected, the anode has been examined for the first time after 2 years and afterwards annually and that the anode has been replaced by an original Wikora anode (individual receipts needed) by a specialized company.
  • Page 8: Installation Record

    In the case of reclamation, the receipts for maintenance must be provided as proof. Please complete the data sheet, including the reason for reclamation, and submit to Wikora. Submitting the maintenance record does not ensure any promise of guarantee or claim.

This manual is also suitable for:

Wbo 2005 duoWbo 3005 unoWbo 3005 duo