    C/ La Banyeta Nova, 11 - P.I. La Banyeta, 17843 Palol de Revardit (Girona) - Catalonia - Spain Description of product VKDROO series are the immersion type mult multistage centrifugal pump with standard motor. Two pumpheads are available, Cast iron type (HT200) and Stainless steel type. Other wet parts are all made of stainless steel (SS304 or SS316) by punching and welding.
  • Page 3: Applications

    VKF,VKX,VKN 1,2,3,4 I. GENERal VKDROO Series are the immersion type multisatge centrifugal pump with standard motor. It adopts the most advanced structure in the world. Pump head has two types, cast iron type (HT200) and stainless steel tyoe. Other wet parts are all made of stainless steel (SS304 or SS316) by punching and welding.
  • Page 4: Definition Of Model

    IV. DEFINItION OF mODEl V. StRUctURE VKDROO Series are vertical multi-stage, segmental type, centrifugal pump. Motor is directly connected with pump shaft by coupling of pump head. Inlet is at the bottom of VKF,VKX,VKN 1,2,3,4,8,16,20,32,42 pump and outlet is at the bottom of motor.
  • Page 5: Assemble And Disassemble

    VIII. aSSEBlE aND DISaSSEmBlE IX. FaUlt FINDING aND SOlUtION cHaRt 1. VKDROO 1,2,3,4,8,16,20 Fault Cause Solution 1) Put the circlip cover on the shaft. 1. Power supply fails 1. Check power supply 2) Fit the impeller, impeller sleeve, diffuser, support diffuser, etc. Continue the Motor can’t be started 2.
  • Page 6: Dimensions

    X. DImENSION VKDROO 1,2 50Hz VKDROO 3,4 50Hz Size of single phase motor, anti-explosive motor will be different, please check with us Size and weight Size and weight Installation Sketch Installation Sketch Model Pump and motor Weight Model Pump and motor Weight dimensions (kg)
  • Page 7 VKDROO 8,16 50Hz VKDROO 20 50Hz Size and weight Size and weight Installation Sketch Installation Sketch Model Pump and motor Weight Model Pump and motor Weight dimensions (kg) dimensions (kg) VKDROO 8-20/2 VKDROO 20-20/2 VKDROO 8-30/3 VKDROO 20-30/3 VKDROO 8-40/4 VKDROO 20-40/4 VKDROO 8-50/5 VKDROO 20-50/5...
  • Page 8 VKDROO 32 50Hz VKDROO 42 50Hz Size and weight Size and weight Installation Sketch Installation Sketch Model Pump and motor Weight Model Pump and motor Weight dimensions (kg) dimensions (kg) VKDROO 32-10-1/1 VKDROO 42-10-1/1 702/ 504/ 165/ 197/ VKDROO 32-10-1 VKDROO 42-10-1 VKDROO 32-20-2/2 746/...
  • Page 9 VKDROO 1,2 60Hz VKDROO 3,4 60Hz Size and weight Size and weight Installation Sketch Installation Sketch Model Pump and motor Weight Model Pump and motor Weight dimensions (kg) dimensions (kg) VKDROO 1-20/2 VKDROO 3-20/2 VKDROO 1-30/3 VKDROO 3-30/3 VKDROO 1-40/4 VKDROO 3-40/4 VKDROO 1-50/5 VKDROO 3-50/5...
  • Page 10 VKDROO 8,16 60Hz VKDROO 20 60Hz Size and weight Size and weight Installation Sketch Installation Sketch Model Pump and motor Weight Model Pump and motor Weight dimensions (kg) dimensions (kg) VKDROO 8-20/2 VKDROO 20-20/2 VKDROO 8-30/3 VKDROO 20-30/3 VKDROO 8-40/4 VKDROO 20-40/4 VKDROO 8-50/5 VKDROO 20-50/5...
  • Page 11 VKDROO 32 60Hz VKDROO 42 60Hz Size and weight Size and weight Installation Sketch Installation Sketch Model Pump and motor Weight Model Pump and motor Weight dimensions (kg) dimensions (kg) VKDROO 32-10-1/1 VKDROO 42-10-1/1 VKDROO 32-10-1 VKDROO 42-10-1 VKDROO 32-20-2/2 VKDROO 42-20-2/2 1010 278 VKDROO 32-20-2...
  • Page 12 XI. DRawING VKDROO 8,16,20—090902 Motor 13. Bearing 25. Washer Coupling 14. Support diffuser 26. Nut VKDROO 1,2,3,4—111102 Pump head 15. Strainer 27. Air vent gag Coupling guard 16. Shaft pin (optional) Motor 11b. Neck ring 21. Washer Mechanical seal 17. Circlip cover 28.
  • Page 13: Warning

    XII. waRNING A. Before opening the terminal box, please shut off the power supply to prevent from electric shock B. Before opening the coupling guard, please stop pump fistly to prevent from hurt. C. When installing the pump, please fix the foundation bolts vertically to prevent from pump falling to hurt people.
  • Page 14: Important Notice

    XII. ImpORtaNt NOtIcE Notes 1. Customers will not be advised if this manual is updated. 2. Pump will be guaranteed for one year under normal operation with the correct model. Wearing part is not included. 3. Users shall be responsible for the damage if they dissemble the pumps by themselves in guaranteed period.