Smartgen AIN16-M01 User Manual

Analog integrated module

Advertisement

Quick Links

AIN16-M01
ANALOG INTEGRATED MODULE
USER MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Smartgen AIN16-M01

  • Page 1 AIN16-M01 ANALOG INTEGRATED MODULE USER MANUAL...
  • Page 2 SmartGen Technology reserves the right to change the contents of this document without prior notice. Table 1 - Software Version Date...
  • Page 3 This user manual only suits for AIN16-M01 Analog Integrated Module. Table 2- Notation Clarification Symbol Instruction Highlights an essential element of a procedure to ensure correctness. NOTE Indicates a procedure or practice, which, if not strictly observed, could result in CAUTION damage or destruction of equipment.
  • Page 4 5.3 PARAMETER CONFIGURATION ....................... 9 5.4 PTIN1~PTIN8 AND CIN1 SETTINGS ..................... 10 5.5 MP1~MP3 SETTINGS ........................11 5.6 AOUT1~ AOUT4 SETTINGS ......................11 ELECTRICAL CONNECTIONS ......................... 12 INSTALLATION ............................12 TROUBLE SHOOTING ..........................13 AIN16-M01 Analog Integrated Module User Manual Page 4 of 13...
  • Page 5: Performance And Characteristics

    1 OVERVIEW AIN16-M01 analog integrated module contains 8 PT100 sensor input channels, 3 speed input channels, 4 4~20mA output channels and one 4~20mA input channel. The data are transmitted to the HMC9000 controller for processing via CANBUS port, then HMC9000 transfers 4~20mA data back into AIN16-M01 module via CANBUS port and AIN16-M01 outputs corresponding 4~20mA signals.
  • Page 6 COM3 AOUT3 0.5mm 4~20mA output port mAOUTPUT3 4~20mA output common port COM4 AOUT4 0.5mm Sensor terminal mAOUTPUT4 COM(B+) 4~20mA analog input. CIN1 0.5mm B+ input (supply power for pressure transmitter) AIN16-M01 Analog Integrated Module User Manual Page 6 of 13...
  • Page 7 0.5mm PTIN7 0.5mm PTIN8 0.5mm HMC9000 can connect to two AIN16-M01 modules at the same time. Address selection : It is module 1 when the switch 1 is connected to terminal 12 while module 2 when connect to ON SWITCH terminal.
  • Page 8 5 PROTECTION All data can be protected via HMC9000 controller. HMC9000 can connect to two AIN16-M01 modules at the same time and users can select module address via dial switch. Following parameters can be set via HMC9000: AIN16-M01 module enable: HMC9000 can communicate with the module and collect the data;...
  • Page 9 MP1~MP3 Set Delay/ High Warn Enable / High Warn Value / High Return Value / High Warn Delay 4~20mA Output Set Output can be configured as relevant to the sensor AIN16-M01 Analog Integrated Module User Manual Page 9 of 13...
  • Page 10 User can reset the sensors’ names which are displayed on HMC9000 LCD. e.g. rename sensor 1 as Temperature Exhaus User-defined string sensor. User-defined string can be edited via HMC9000 PC software only. AIN16-M01 Analog Integrated Module User Manual Page 10 of 13...
  • Page 11 AIN16-M01 Module1 PT00 Sensor 1~8 via CANBU. AIN16-M01 Module1, 4~20mA Sensor 1 91~93 AIN16-M01 Module2 Speed 1~3 94~101 AIN16-M01 Module2 PT00 Sensor 1~8 AIN16-M01 Module2, 4~20mA Sensor 1 102~149 Reserved AIN16-M01 Analog Integrated Module User Manual Page 11 of 13...
  • Page 12: Electrical Connections

    6 ELECTRICAL CONNECTIONS Fig.2- AIN16-M01 Electrical Connection Diagram Fig.3- HMC9000 with two AIN16-M01 modules connection diagram 7 INSTALLATION Fig.4- Overall Dimensions AIN16-M01 Analog Integrated Module User Manual Page 12 of 13...
  • Page 13: Troubleshooting

    Problem Possible Solution Check batteries; Controller no response with power. Check controller connection wirings; Check DC fuse. CANBUS communication failure Check if CANBUS wires are connected in the opposite way. AIN16-M01 Analog Integrated Module User Manual Page 13 of 13...

Table of Contents