Care And Maintenance; Troubleshooting - Kobalt KHB 2580-06 Manual

80v brushless blower
Hide thumbs Also See for KHB 2580-06:
Table of Contents

Advertisement

CARE AND MAINTENANCE

WARNING
In order to avoid personal injury and the risk of fire and electric shock, remove the battery pack before
adjusting, inspecting, or cleaning the blower.
CLEANING
• Remove the battery pack.
• Brush or blow dust and debris out of the air vents using compressed air or a vacuum. Keep
the air vents free of obstructions, sawdust, and wood chips. Do not spray, wash, or immerse the
air vents in water.
• Wipe off the housing and the plastic components using a moist, soft cloth. Do not use strong
solvents or detergents on the plastic housing or plastic components. Certain household cleaners
may cause damage, and may cause a shock hazard.

TROUBLESHOOTING

PROBLEM
Unit will not blow.
Motor fails to start
when switch trigger
is depressed.
Unit will not start.
POSSIBLE CAUSE
1. Blocked tube.
1. Battery is not secure.
2. Battery is not charged.
1. Defective power switch.
CORRECTIVE ACTION
1. Clear the blockage.
1. Ensure the battery is fully secure in
the battery compartment and the
battery release button locks into
place.
(Reference Page 10 of the
instruction manual).
2. Charge the battery pack according
to the instructions included with
your model.
1. Return to place of purchase or re
turn the unit to a repair center or
call customer service at
1-888-3KOBALT (1-888-356-2258).