VSAIL VI-6631 Installation And Operation Manual

Intelligent fixed temperature heat detector

Advertisement

Quick Links

P
l
e
a
s
e
r
e
a
d
t
h
i
s
m
P
l
e
a
s
e
r
e
a
d
t
h
i
s
m

1. Description

VI-6631 Intelligent Fixed Temperature Heat Detector (called the detector for short) using
excellent MCU technology can accurately chase with the variation of environment temperature,
detect fire in-time, and generate fire alarm.
The detector has pleasing appearance and is easy to install and maintain. It is suitable for the
environment without smoke but a lot of dust or the places where smoke and vapor stay such as
indoor parking, kitchen, boiler room, tea stove room, generator room and drying workshop.

2. Features

(1) Built-in ID address of the detector.
(2) Filter designed in both software and hardware, enhance anti-interference ability of the
detector.
(3) Two-wire loop, non-polarized.
(4) Utilizing electronic addressing, makes programming more flexible, simple and user-friendly.
(5) PCB board is sealed totally.
(6) Use thermal components with high sensitivity, enhancing response speed to variation of the
temperature.
(7) Talented design of structure without a single screw.

3. Technical Specifications

(1) Operating Voltage:15V-28V impulse voltage
(2) Operating Current:
1) Loop static current ≤0.5mA
2) Loop alarm current ≤1.0mA
(3) Sensitivity: A2
(4) Wiring: two-wire(non-polarized )
(5) Programming: Electronic addressing
(6) Status Incitation of the detector.
1)Standby: LED flashes periodically.
2)Fire: LED illuminates steadily.
3) Fault warning: LED is off until cleared.
(7) Operating Environment
a)
Temperature:-10℃~54℃
Humidity: ≤93±2%RH(25℃-40℃) ,non-condensing
b)
(8) Color: Gloss-White
(9) Weight: 120g
(10) Standard: GB 4716-2005

4. Structure and Operation Principle

(1) Dimension of the detector is shown in Fig. 1 and Fig. 2 separately.
a
n
u
a
l
c
a
r
e
f
u
l
l
y
b
e
a
n
u
a
l
c
a
r
e
f
u
l
l
y
b
e
VI-6631 Intelligent
Fixed Temperature Heat Detector
Installation and Operation Manual (Ver1.03,August 2014)
f
o
r
e
i
n
s
t
a
l
l
i
n
g
a
n
d
f
o
r
e
i
n
s
t
a
l
l
i
n
g
a
n
d
o
p
e
r
a
t
i
n
g
t
h
e
d
e
v
o
p
e
r
a
t
i
n
g
t
h
e
d
e
v
i
c
e
!
i
c
e
!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VI-6631 and is the answer not in the manual?

Questions and answers

Summary of Contents for VSAIL VI-6631

  • Page 1 Fixed Temperature Heat Detector Installation and Operation Manual (Ver1.03,August 2014) 1. Description VI-6631 Intelligent Fixed Temperature Heat Detector (called the detector for short) using excellent MCU technology can accurately chase with the variation of environment temperature, detect fire in-time, and generate fire alarm.
  • Page 2 Fig. 1 Fig. 2 (2) Operation Principles This product uses the thermistance of negative temperature index. When the temperature rises, the resistance of thermistor is decreasing, which lead to the change of voltage. When the voltage value is bigger than threshold, it reports alarm signal, and the code-returning circuit transmits the signal to the fire alarm control panel and generates the fire alarm.
  • Page 3 Fig. 4 6. Operation Address Programming: Using VI-6631 Hand Held Programmer can program address of the device in field. When programming, first connect two alligator clips of the hand held programmer to the loop-ports of the detector; second, switch on power of the programmer and enter addressable code (code should be from 0 to 255.
  • Page 4 Contact us if any problem occurs. We will provide best solutions. After-sale Hot Line: Tel: 010 56691000 Fax: 010 56691100 Website : www.vsail.com.cn Post Code: 100176 Company: Beijing VSAIL Fire Protection Equipment Co., Ltd. Address: Building 32, Huilongsen Technology Park, No.99 14 Kechuang Street, BDA, Beijing...

Table of Contents