E: 11. Serial Communication Error (Serial Reverse Transfer Error) (Outdoor Unit) - Fujitsu ARXG45KMLA Service Manual

Hide thumbs Also See for ARXG45KMLA:
Table of Contents

Advertisement

2. Troubleshooting with error code
2-1. E: 11. Serial communication error (Serial reverse transfer
error) (Outdoor unit)
→ired remote
Indicator
controller
Detective actuator
Outdoor unit
Forecast of cause
Check point 1. Reset the power and operate
Does error indication show again?
If no, go to
"Check point
Check point 2. Check connection
Check any loose or removed connection line of indoor unit and outdoor unit.
Check connection condition is control unit. (If there is loose connector, open cable or mis-wiring.)
If there is an abnormal condition, correct it by referring to the installation manual or the "DESIGN
& TECHNICAL MANUAL".
Check point 3. Check the voltage of power supply
Check the voltage of power supply
Check if AC 198 V (AC 220 V -10%) to AC 264 V (AC 240 V +10%) appears at
outdoor unit terminal L - N.

2-1. E: 11. Serial communication error (Serial reverse transfer error) (Outdoor unit)

Error code
Main PCB
→hen the indoor unit cannot receive the serial signal
from outdoor unit more than 2 minutes after power on,
or the indoor unit cannot receive the serial signal more
Fan motor
than 15 seconds during normal operation.
1-2".
- (03-4) -
E: 11
Connection failure
External cause
Main PCB failure
Outdoor unit fan motor failure
2. Troubleshooting with error code
+
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Arxg36kmlaAoyg36krtaAoyg45krta

Table of Contents