Advanced settings (TIP: this can be done easily through the App)
To activate the advanced menu: Turn off the thermostat (press and hold "O" for 5 sec).
1. press and hold the "+" and "-" buttons for 3 seconds (Display shows "0 1").
2. Press "+" or "-" to select a the option (0 1 - 10)
3. Briefly press "O" to select and then "+" or "-" to adjust the parameter.
4. Briefly press "O" to exit the option (Follow again from point 2 to adjust other options).
5. Save: Press and hold "O" to save all settings and turn the device off again.
Option Function
Temperature calibration
0 1
Maximum temperature setting
02
Minimum temperature setting
03
Screen illumination
04
Water resistance
05
Allow key distribution
06
Sensor selection
07
Maximum floor temperature
08
Frost protection
09
Pump delay (0-3 minutes)
1 0
(Master thermostat only)
Factory settings: Long press "+" and "-" at the same time, "dEf "should flash 3 times.
Parameters
-6°C ~ +6°C
25~50°C
5~20°C
1: Always on
2: 10 seconds on, then 50% dimmed.
3: 10 seconds on, then display off and "O" 50% dimmed.
On/Off
On/Off
S-r / r-F / S-F (See page 41)
5~70°C
On/Off
1-3: 1, 2 or 3 minutes delay for pump and boiler.
0: No delay for pump and boiler.
42
Default
0°C
35°C
10°C
2
On
On
S-r
40°C
On
3