Description View field(diagonal length) 1.15mm~7.5mm(1X auxiliary objective), 2.3mm~15mm(0.5X auxiliary objective) Magnification (19" widescreen display) 44X~280mm(1X auxiliary ISD-A100 is a precise and excellent effective measuring objective), 22X~140X(0.5X auxiliary objective) instrument integrating optic, mechanic and electricity. Used Accuracy: ≤4µm widely in the trade of mechanic, meter, electronics and light industry, as well as the laboratories, metric room and workshop of Repeatability µm...
Page 3
Select “I Agree...”then click “Next”. As the following picture: Y axis adjustment X axis adjustment Turn X, Y axis adjustment knob the stage. Note: The scale on the stage just for reference but not for measuring. Choose the Install Path then click “Next”: Power connection: Insert the surface illumination plug into the top of stand, then confirm the voltage is same as local voltage.
Page 4
Click “Next”. As the following picture: Click “Next” to install the software. If appear the windows as follow, please click “OK” and “Ignore” to continue: Click “I Agree” to continue. As the following picture: When appear window as follow, please click “Finish”。 Select “...
If the view filed is not enough, Operation attention please use the 0.5X auxiliary objective. If you computer use Windows 7 OS, please right click “INSIZE Illumination selection MS” icon on the desktop and select properties. Then click “Compatibility”...
Page 6
white line The color is blue adjusting knob When magnification is large, just set the max brightness. View field Replace the auxiliary objective: U s e t h e 1 . 5 m m a l l e n w r e n c h ( s t a n d a r d d e l i v e r y ) t o In order to get the measuring accuracy, you must magnify the object disassemble the surface illumination.
Note: You don’t need calibration if focusing again. 1. Create new file: Create a new “ INSIZE MS” file with the extension “e2d”. Put the calibration block on the stage and choose contour 2.
Page 8
3. Save file: save present work. 4. Arc drawing: Input at least three points, the first point as 4. Output as “ Word” : If “ Microsoft office” is installed in your the start point, the second point to determine arc direction and the last point as the end point.
Page 9
14. Point-select circle: Use left mouse key to click in the circle, 25. Circle-circle intersections: Press down Icon use right mouse the program will take this point as a center and then look for the key to select two circles (one by one), program will calculate edge around, and use the edge data acquired to regress a circle.
Page 10
Optional setting: Input CAD graph to compare with the workpiece: Settings to the program, such as Auto-Save function. First you need use CAD software draw the graph. The Result dialog box: absolute coordinate of CAD software and measuring software must be consistent as follow. Display the name and measure result of the objects, also you can select and delete the objects.