POMCube iCAN NetZero Plus User Manual page 32

Hide thumbs Also See for iCAN NetZero Plus:
Table of Contents

Advertisement

Install the bracket and battery system on the wall with
(6)
M6x50 tapping screws.
N N O O T T E E :
If you are installing it on a concrete wall, properly
drill into the wall with M6x50 tapping screws and plastic
anchors.
CAUTION: Dust collection is required during
drilling.
CAUTION: Make sure the cabinet is firmly on the
floor. The wall bracket is only designed to keep
the battery system from tipping forward, not
supporting the weight of the battery.
Hang the inverter on the bracket.
(7)
N N O O T T E E :
Before installing Universal PCS, remove
the battery seal cap (BAT/COM) on the bottom
of Universal PCS.
/