11. Replace the pressure release
tube. Tighten nuts.
12. Replace the outlet tube and
tighten nuts.
13. Replace shrouds, console and
regulator ring.
14. Perform the Break-in Procedure.
See "Break-in Procedure" in the
Operation section.
To Replace Regulator
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Set the On/Auto/Off lever to
"OFF" and unplug unit.
3.
Remove the regulator ring and
Regulator
Ring
remove the console cover.
4.
Using an adjustable wrench
loosen pressure relief tube nut at
air tank and pressure switch.
5.
Using an adjustable wrench,
rotate the pressure switch
assembly as shown.
Regulator
Outlet
Pressure
Gauge
6.
7.
8.
9.
NOTE: Arrow indicates flow of air.
Make sure it is pointing in the
direction of air flow.
Cover
10. Reapply pipe sealant to outlet
11. Reassemble outlet pressure
12. Rotate pressure switch assembly
13. Replace console cover and
Tank
Pressure
Gauge
Quick
Connect
19- ENG
Remove the outlet pressure
gauge, tank pressure gauge, and
quick connect (if equipped) from
the regulator.
Remove the regulator.
Apply pipe sealant tape to the
nipple.
Assemble the regulator and
orient as shown.
Regulator
Arrow
pressure gauge, tank pressure
gauge, and quick connect.
gauge, tank pressure gauge, and
quick connect. Orient outlet
pressure gauge and tank
pressure gauge to read correctly.
Tighten quick connect with
wrench.
into correct position.
regulator ring.
D26706