8.
CAUTION!
Install the appliance only on
a worktop with flat surface.
3.9 Possibilities for insertion
The panel installed below the hob must
be easy to remove and let an easy
access in case a technical assistance
intervention is necessary.

4. INSTALLATION

WARNING!
Refer to Safety chapters.
4.1 Before the installation
Before you install the hob, write down the
information below from the rating plate.
The rating plate is on the bottom of the
hob.
Model .......................................
PNC .........................................
Serial number ...........................
4.2 Important safety
requirements
This hob must be installed in accordance
with the Gas Safety (Installation and
Use) Regulations (Current Edition) and
the IEE Wiring Regulations (Current
Edition).
For appliances installed in the Republic
of Ireland please refer to NSAI- Domestic
Gas Installation I.S. 813 Current Editions
and the ETCI Rules for Electrical
Installations.
Kitchen unit with door or drawer
A
60 mm
B
A. Removable panel
B. Space for connections
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
Provision for ventilation
Detailed recommendations are contained
in the following British Standards Codes
Of Practice: B.S. 6172/B.S. 5440, Par. 2
and B.S. 6891 Current Editions.
The hob should not be installed in a bed
sitting room with a volume of less than
20 m³. If it is installed in a room of
volume less than 5 m³ an air vent of
effective area of 100 cm² is required. If it
is installed in a room of volume between
5 m³ and 10 m³ an air vent of effective
area of 50 cm² is required, while if the
volume exceeds 11 m³ no air vent is
required.
However, if the room has a door which
opens directly to the outside no air vent
is required even if the volume is between
5 m³ and 11 m³.
If there are other fuel burning appliances
in the same room, B.S. 5440 Part 2
Current Edition, should be consulted to
determine the requisite air vent
requirements.
For appliances installed in the Republic
of Ireland please refer to the NSAI-
Domestic Gas Installation I.S. 813
Current Editions Table Four.
ENGLISH
13
30 mm
min 20 mm
(max 150 mm)

Advertisement