Operating Instructions
The control panel has three AC breakers: Two (2) 20 A breakers for the 5-20R split duplex receptacle,
and one (1) 30 A breaker for the L5-30R twist-lock receptacle. The 20A breakers each protect one of
the circuits in the 5-20R split duplex receptacle; the left 20A breaker protects the top receptacle, and
the right 20A breaker protects the bottom receptacle.
Ensure that the breaker is on for the receptacle you want to use.
1. Start the engine.
2. Make sure the digital display is illuminated and returning data.
3. Confirm that the appliance to be used is switched off before plugging into the control panel.
4. Plug the appliance into the control panel.
The low oil alarm system is designed to prevent engine damage caused by an insufficient amount
of oil in the crankcase. Before the oil level in the crankcase falls below a safe limit, the low oil alarm
system will automatically shut down the engine (the ignition switch will remain in the "ON" position).
If the low oil sensor shuts down the engine, the low oil light (red) will come on when you operate the
starter, and the engine will not run. If this occurs, add enough of the approved engine oil to raise the
level to the top line on the dipstick.
BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
& Owner's Manual

AC APPLICATION

LOW OIL ALARM SYSTEM
39
39