EXERCISING THE GENERATOR

It is essential that the generator be exercised on a regular basis. This will prevent the accumulation
of varnish or sludge in the fuel system; remove moisture from the generator windings and help
keep the battery properly charged. Additionally, the engine seals and moving components will be
lubricated. Exercise the generator by running it with at least a 1/2 load (2000W) for 15 minutes per
month. Gasoline fuel treatments (such as STA-BIL®) to prevent contamination of your fuel supply are
available from your dealer.
NOTE: Fuel varnishing necessitating replacement of the fuel injector is not
a warrantable failure.
IF THE ENGINE WILL NOT START:
1. Check to ensure switches are in the "ON" position.
2. Check engine oil level. Your unit possesses a Low Oil Alarm System that will not allow your
engine to start if the oil is below safe operating levels. This feature is installed to increase the
life of your engine and prevent engine damage. If oil level is low, fill to the full mark on dipstick.
Refer to the Product Specifications for exact oil type and amounts.
3. Add fuel stabilizer. Turn fuel shut-off valve to "off" position, run unit until fuel in fuel lines and
carburetor has burned out of system.
4. Check the fuel level to insure adequate fuel. Add fuel if necessary.
5. Remove and inspect the spark plug for cleanliness and proper electrode gap. If needed, clean
or replace the spark plug. Refer to Spark Plug Maintenance in the Maintenance section of the
Owner's Manual for proper procedure.
NOTE: Periodically on the initial start-up or after the unit has been stored
for a long period of time, the float for the "Low Oil Alarm System" will stick
to the bottom of your oil pan. Locate the two (2) wires to the Low Oil Sensor
Diode (refer to figure on the right) located on the side of the engine block.
Unplug these wires and, only after ensuring the engine is full of oil, start the
engine and allow to run until warm (normally 20 minutes, as this will heat the
oil and release the float on the Low Oil Alert System). Then re-plug the wires
to the terminals on the Low Oil Alarm Sending Unit.
UNIT DOES NOT PROVIDE ELECTRICAL CURRENT:
1. Plug in a small appliance or tool to test.
2. Check if the AC (or DC) Circuit Breaker is in the "ON" position. If not, place in "ON" position.
3. If your unit still does NOT produce electricity after performing the previous checks, call BRAVE at
1-888-980-4938, your dealer, or authorized Service Center.
38
38
Operating Instructions

TROUBLESHOOTING

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938