Page 1
Wood Stove Owner's Manual Part 2 of 2 INSTALLATION AND OPERATION REQUIREMENTS HES140 (VB00023 model) US Environmental Protection Agency phase II certified wood stove compliant with 2020 cord wood standard Safety tested according to ULC S627, UL 1482 and UL 737 standards by an accredited laboratory.
Page 2
Dealer: Installer: Phone Number: Serial Numbrer: ONLINE WARRANTY REGISTRATION If the unit requires repairs during the warranty period, proof of purchase must be provided. The purchase invoice must be kept. The date indicated on it establishes the warranty period. If it can not be provided, the warranty period will be determined by the date of manufacture of the product.
This appliance is officially tested and certified by an independent agency. Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17 based on the ALT-125 sent by EPA on February 28 , 2018. Carbon monoxide. Installation and Operation Requirements - HES140 Page 5...
CAN/CSA- Z240 MH standard. Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and draft ASTM WK47329-14. Based on ALT-125 sent by EPA on February 28th, 2018. Page 6 Installation and Operation Requirements - HES140...
Leave to burn with the primary air control open for approximately 10 minutes and then close the primary air control completely for the low burn rate and halfway for the medium burn rate. Installation and Operation Requirements - HES140 Page 9...
12 7/8" (327 mm) 12 7/8" (327 mm) The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Page 10 Installation and Operation Requirements - HES140...
Page 11
48" Flush 48" 36" 122 cm 92 cm Figure 7: Clearances - Top Figure 8: Clearances - Corner 84" 213 cm Figure 9: Clearances - Side Installation and Operation Requirements - HES140 Page 11...
Page 12
6" from combustible materials must be used. Only in this case, the same clearances as a certified double wall pipe connector can be used. The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Page 12 Installation and Operation Requirements - HES140...
Page 13
12 7/8" (327 mm) 12 7/8" (327 mm) The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Installation and Operation Requirements - HES140 Page 13...
Page 14
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Page 14 Installation and Operation Requirements - HES140...
Page 15
12 7/8" (327 mm) 12 7/8" (327 mm) The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Installation and Operation Requirements - HES140 Page 15...
Page 16
Les distances de tuyau listées dans ce tableau se réfèrent aux distances obtenues lorsque le poêle est installé en accord avec les dégagements de l’appareil mentionnés ci-dessus. Page 16 Installation and Operation Requirements - HES140...
The floor protection at the back of the stove is limited to the stove’s required clearance if such clearance is smaller than 8 inches (203 mm). Only required under the horizontal section (Ho) of the connector. Must exceed each side of the connector by at least 2 inches (51 mm). Installation and Operation Requirements - HES140 Page 17...
Mounting hardware must not be located closer than 8" (200 mm) from the vertical centre line of the appliance. G) Edge clearance for ceiling shields to side and back walls: 3" (75 mm) Shield extension beyond each side of the appliance: 18" (450 mm) Page 18 Installation and Operation Requirements - HES140...
Page 20
Brick, with a minimum of 24 gauge (0.61 mm) sheet metal backing, spaced out at least 1" (25 mm)* by non-combustible spacers 12" (305 mm) * In Canada this space can be ⅞" (21 mm) Page 20 Installation and Operation Requirements - HES140...
(HVAC type, must meet ULC S110 or UL 181 class 0 or class 1) (B), sold separately. Refer to air intake kit installation instructions for more details. Page 22 Installation and Operation Requirements - HES140...
Lift the fire screen upwards and push the bottom part towards the stove then let the fire screen rest on the bottom of the door opening. Warning: Never leave the stove unattended while in use with the fire screen. Installation and Operation Requirements - HES140 Page 23...
Ensure that the blower’s power cord is not in contact with any surface of the stove to prevent electrical shock or fire damage. Do not run the power cord beneath the stove. Page 24 Installation and Operation Requirements - HES140...
Make sure the notch reaches the end of the key way. Put the baffle in place. Repeat steps 1 and 2 for the three other tubes. To remove the tubes use the above steps in reverse order. Installation and Operation Requirements - HES140 Page 25...
Page 26
Note that secondary air tubes (B) can be replaced without removing the baffle board (A) and that all tube are not necessarely identical (look at the part number on the tube). Page 26 Installation and Operation Requirements - HES140...
Mobile Home Installation THE IMAGES SHOWN ARE INDICATIVE ONLY AND MAY DIFFER OF YOUR PRODUCT, BUT THE ASSEMBLY REMAINS THE SAME. Screw the base on the floor with the proper hardware (O). Installation and Operation Requirements - HES140 Page 27...
Reinstall the glass, being careful to centre the glass in the door and not to over-tightening the retaining screw. The two main causes of broken door glass are uneven placement in the door and over-tightening the retaining screws. Page 28 Installation and Operation Requirements - HES140...
Remove the split pin by pulling and turning it using pliers. Turn the handle one counterclockwise turn to increase pressure. Reinstall the split pin with a small hammer. Figure 15: Removing the split pin Figure 16: Installing the split pin Installation and Operation Requirements - HES140 Page 29...
Page 30
Using a flat screwdriver, turn the adjustable hinge rods in the direction shown to adjust the doors. Tighten all door hinge pressure screws when they are at the desired positions. Configurations 1-2-3-4-5-6, show in which direction these act on the adjustment of the door. Page 30 Installation and Operation Requirements - HES140...
Page 31
Leave about ½" long of the gasket when cutting and press the end into the groove. Tuck any loose fibers under the gasket and into the silicone. Close the door. Do not use the stove for 24 hours. Installation and Operation Requirements - HES140 Page 31...
8. Exploded Diagram and Parts List Page 32 Installation and Operation Requirements - HES140...
Page 33
3/4" X 6' FLAT BLACK SELF-ADHESIVE GLASS GASKET 30101 SPRING TENSION PIN 5/32"Ø X 1 1/2"L SE24352 VENTIS 1.4 DOOR WITH HANDLE AND GASKET AC06500 SILICONE AND 5/8" X 8' BLACK DOOR GASKET KIT SE70697 REPLACEMENT HANDLE WITH LATCH KIT...
Page 34
CROSSFLOW BLOWER 115V-60Hz-39W 100 CFM 60013 POWER CORD 96" X 18-3 type SJT (50 pcs per carton) AC01336 5"Ø FRESH AIR INTAKE KIT FOR WOOD STOVE ON PEDESTAL 49028 5" WHITE AIR INTAKE TERMINATION Page 34 Installation and Operation Requirements - HES140...
Labour cost and repair work to the account of the manufacturer are based on a predetermined rate schedule and must not exceed the wholesale price of the replacement part. Shall your unit or a components be defective, contact immediately your VENTIS dealer. To accelerate processing of your warranty claim, make sure to have on hand the following information when calling:...
Page 36
This document is available for free download on the Stove Builder International inc. manufacturer’s website. It is a copyrighted document. 250, rue de Copenhague, Resale is strictly prohibited. The manufacturer may update St-Augustin-de-Desmaures (Québec) Canada this document from time to time and cannot be responsible G3A 2H3 for problems, injuries, or damages arising out of the use 418-908-8002...
Need help?
Do you have a question about the HES140 and is the answer not in the manual?