Page 1
COMPLETE INSTALLATION AND TROUBLESHOOTING GUIDE Model 00600-M Model 00500-M ShrinkPRO ShrinkPRO Quencher Techniks is a proud member of Techniks Tool Group. Connect with Techniks Tool Group Techniks Inc. 9930 E. 56th St. Indianapolis, IN 46236 | 800.597.3921 | www.techniksusa.com | info@techniksusa.com...
Page 2
• Unauthorized modifications changes tripping hazard for personnel. to the ShrinkPRO machine will VOID your manufacturer’s warranty. Do not try and service • Do not operate the machine in a wet environment your unit yourself. Techniks can provide any where exposure to coolant or spills are likely necessary repairs or maintenance.
Page 3
Do not be alarmed if you hear this tone as it is normal. SHRINKFIT TOOLHOLDERS Techniks ShrinkPRO machines make it easy and safe to perform shrink fit tool changes without causing damage to the toolholder or cutting tool, as long as the machine is correctly installed and proper operating procedures are followed.
00600-M PARTS IDENTIFICATION & MACHINE REQUIREMENTS EACH SHRINKPRO AND QUENCHER SHIPS WITH: FEATURES Part No. Description • Induction coil technology enables 00165 Induction Ring (3 - 5mm shanks) tool changes in 3-6 seconds 00166 Induction Ring (6 - 12mm shanks)
Page 5
The Quenching Time and coolant flow must be set to provide adequate cooling time to protect Model 00500-M ShrinkPRO Quencher personnel from injury caused by improperly cooled toolholders. width 36.75" x depth 24" x height 71" - Weight: 292 lbs...
SETUP & INSTALLATION SHRINKPRO SETUP • The 00600-M ShrinkPRO requires a level, stable surface and good ventilation for proper operation. Keep the machine clean and dry at all times. • Connect the machine to your power supply. The machine operates on 208V-480VAC on a 3-phase 30 amp circuit.
OPERATIONS GUIDE INSERTING YOUR CUTTING TOOL • Choose the toolholder seat that corresponds with your toolholder. • Place the seat over the pedestal hole and insert your toolholder. • Choose the induction stop ring that corresponds with your toolholder. • Place the stop ring into the induction head, rotate it 90˚ to secure its position.
Page 8
OPERATIONS GUIDE COOLING CYCLE (00600-M SHRINKPRO) • The cooling cycle automatically begins 5 seconds after the heating cycle ends. The cooling cycle automatically stops after 3 minutes. • You can manually stop the cooling cycle after 30 seconds by touching the “Head Air Off” button.
Page 9
• Remove, clean and replace the strainer from the pump inlet hose in the tank. • Add 1 gallon CIMTECH 310 (Techniks Part No. 00500-C) to 20 gallons fresh water. Refill the tank with clean approved coolant and run a Quench cycle to verify coolant is flowing properly.
Page 16
Satisfaction guaranteed on all our CNC tooling solutions | www.techniksusa.com...
Page 17
• Locked drive on standard carbide round shanks Techniks is a proud member of Techniks Tool Group. Connect with Techniks Tool Group Techniks Inc. 9930 E. 56th St. Indianapolis, IN 46236 | 800.597.3921 | www.techniksusa.com | info@techniksusa.com...
Need help?
Do you have a question about the SHRINKPRO and is the answer not in the manual?
Questions and answers