Summary of Contents for techo-bloc FOYER Brandon Rectangle

  • Page 1 Brandon Rectangle FOYER Installation guide and owner’s manual...
  • Page 2: Table Of Contents

    PLEASE SAVE THIS OWNER’S MANUAL FOR FUTURE REFERENCE Check with your municipality for regulations on the installation and use of outdoor fire pits. We also recommend that you contact your home insurance company and advise them of the acquisition of your new Techo-Bloc fire pit.
  • Page 3: Components

    I MP ORTA NT This fire pit is for OUTDOOR USE ONLY. NEVER build a fire pit for use in a house, warehouse, gazebo, garage, or any other indoor setting. Check with your municipality for minimum clearance distances . Make sure that there is nothing directly above the fire pit area that can be a potential fire and/or injury hazard (e.g.
  • Page 4: Overall Dimensions

    C. RAFFINATO CAP 60 mm (PRE-CUT) BLOCK (GAS KIT) D. BRANDON 90 mm BLOCK RECOMMENDED LOCATION FOR VENT ACCESSORY (GAS KIT); E. TECHO-BLOC PAVERS OR SLABS QUANTITY OF MATERIALS REQUIRED RECOMMENDED LOCATION FOR SECTION 1-1 NOTE : Secure the blocks...
  • Page 5: Positioning Reference Per Layer

    Positioning reference per layer Foundation preparation FOR A GAS FIRE PIT, PLAN THE INSTALLATION (GAS LINE, RISER) ACCORDINGLY PAVER SURFACE OR CONCRETE SLAB WITH A PROFESSIONAL LOCALLY If you are building the fire pit on an existing paver surface LICENSED BY THE AUTHORITY or concrete slab, drill through the pavement to provide a HAVING JURISDICTION 2" diameter drain hole at the lowest point.
  • Page 6: Installation Of Blocks

    FINAL DESIGN SHOULD BE APPROVED BY A QUALIFIED, FINAL DESIGN SHOULD BE APPROVED BY A QUALIFIED, 1-877-832-4625 1-877-832-4625 SHEET: SHEET: LICENSED PROFESSIONAL ENGINEER. LICENSED PROFESSIONAL ENGINEER. TECHO-BLOC OUTDOOR FEATURES TECHO-BLOC OUTDOOR FEATURES www.techo-bloc.com www.techo-bloc.com TYPICAL DETAILS FILE: TYPICAL DETAILS FILE:...
  • Page 7: Operation And Maintenance

    SHOULD NOT BE USED FOR CONSTRUCTION. NONE FINAL DESIGN SHOULD BE APPROVED BY A QUALIFIED, 1-877-832-4625 SHEET: LICENSED PROFESSIONAL ENGINEER. RECOMMENDED LOCATION ON LAYER 3 TECHO-BLOC OUTDOOR FEATURES www.techo-bloc.com FOR VENT ACCESSORY (GAS KIT) TYPICAL DETAILS FILE: BRANDON 90 mm C BRANDON 90 mm CORNER...
  • Page 8 › Do not burn charcoals, leaves, trash, paper, cardboard, and softwoods such as pine, cedar and plywood. › Do not use lighter fluid, gasoline, or other fire accelerants to start or maintain fires. › Never touch the steel insert and flange while a fire is lit. The steel insert and flange will become extremely hot and burn the skin on contact.
  • Page 9: Warranty

    *HPC / TECHO-BLOC PARTNERSHIP WARRANTY OUTDOOR FIRE PIT COMPONENTS RESIDENTIAL COMMERCIAL Fire Pit Stainless Steel Burner Lifetime Lifetime Outdoor Fireplace Burner Lifetime Lifetime Electronic Ignition Components 3 Years 1 Year Pilot Assemblies 2 Years 1 Year Stainless Steel Components 5 Years...
  • Page 10 5135 Surrett Dr., Archdale, NC 27263 OHIO 97 Industrial St., Rittman, OH 44270 PENNSYLVANIA 852 W. Pennsylvania Ave., Pen Argyl, PA 18072 PENNSYLVANIA 23 Quarry Rd., Douglassville, PA 19518 C O N T A C T U S TOLL FREE: 1.877.832.4625 WWW.TECHO-BLOC.COM PROUD MEMBER OF...