LG LUTD4919SN Owner's Manual page 21

Dual fuel range
Hide thumbs Also See for LUTD4919SN:
Table of Contents

Advertisement

Use the cord/conduit connection plate to install the
power cord or conduit. Leave the connection plate
as installed for power cord installations. Remove the
connection plate for conduit installations and use the
smaller 1
/
in. (2.8 cm) conduit hole instead of the
1
8
1
/
in. (3.5 cm) power cord hole.
3
8
1
1
/
" (2.8 cm) Conduit
8
1
/
" (3.5 cm) Cord
3
8
Remove the Conduit connection plate
For power cord installations, hook the strain relief
over the 1
/
in. (3.5 cm) power cord hole located
3
8
below the rear of the oven. Insert the power cord
through the strain relief and tighten it.
Assembling power cord strain relief at the 1
For conduit installations, insert the conduit strain
relief in the 1
/
in. (2.8 cm) conduit hole. Then install
1
8
the conduit through the body of the strain relief and
fasten the strain relief with its ring.
Ring
Body
Assembling conduit cord strain relief at the 1
3-Wire Connection : Power Cord
• The middle (neutral or ground) wire, which
Install the power cord as follows:
For power cord installations, hook the strain relief
over the power cord hole (1
rear of the oven. Insert the power cord through the
strain relief and tighten it.
Do not install the power cord without a strain
relief.
1
Conduit
connection
plate
2
Power cord
3
3
/
" opening
8
3-wire connection
Cord/
Conduit
connection
plate
Conduit
Conduit
connection plate
1
/
" opening
8
If screws are not tightened securely, it can result in
electrical spark and severe personal injury or death.
WARNING
is white, of a 3-wire power cord or a 3-wire
conduit has to be connected to the middle
post of the main terminal block. The
remaining two wires of the power cord or
conduit have to be connected to the outside
posts of the main terminal connection block.
Failure to do so can result in electrical shock,
severe personal injury or death.
/
3
Remove the lower 3 screws from the terminal
block and retain them.
Insert the 3 screws through each power cord
terminal ring and into the lower terminals of
the terminal block. Make sure that the center
(neutral) wire, which is white, is connected to the
center lower position of the terminal block.
Tighten the 3 screws securely into the terminal
block. Do not remove the ground strap
connections.
Black White Red
INSTALLATION
21
") located below the
8
Terminal
block

Advertisement

Table of Contents
loading

Table of Contents