PT1200i
1200W
INVERTER GENERATOR
ECO Throttle
When the Throttle switch is in the
"ON" position the throttle controls
the engine speed according to the
connected electrical load. The
results are better fuel consumption
and less noise. When the switch is
in the "OFF" position the engine
runs at 4,500 rpm regardless of the
electrical load.
Note:
The Throttle must be "OFF" when
using electrical devices that require
a large starting current, such as a
ompressor, pump, or refrigerator.
LED Indicators
The LED Indicators assist in
communicating status and functions
of the unit.
Output Indicator (Green)
The Output Indicator comes on when
the engine starts and produces power.
Overload Alarm (Red)
The Overload Alarm comes on when
a connected device requires more
power than the generator is able to
produce, The Output Indicator (Green)
will go off and the Overload Alarm (Red)
will stay on, but the engine will continue
to run
CAUTION: Do not overload
the generator
Low Oil Alarm (Red)
When the engine oil falls below the
required level the Low Oil Alarm will
come on .and the engine will stop
automatically. The engine will not
restart until oil is added to the unit to
bring it up to the appropriate level.
To Reset the Generator
1.Turn off any connected electric devices and stop
the engine.
2.Reduce the total wattage of connected electric devices
within the rated output.
3.Use in proper ventilated areas. Maintain at least 3ft of
clearance on all sides for adequate cooling.
4.After checking, restart the engine. ( refer to part 3.4
in this manual for how to start).
www.powertec.net.nz
Note:
The Overload Alarm may come on for
a few seconds when first using electrical
devices that require a large starting
current, such as a compressor, pump,
or refrigerator. This is normal and not
a malfunction.
Note:
When starting the unit, if the Low Oil
Alarm light flickers and the engine will
not start, you will need to add engine
oil before attempting to restart the
engine.
Note:
Generator should only be operated on
a level surface. DO NOT operate the
generator on loose ground or obvious
inclines. The low oil shutdown feature
may be prematurely activated in these
cases causing the engine to not start.
Parrallel Output
Two generators can be
connected to increase
output. Put parallel wire
into the socket first, then
start the two greater wattage
as the normal process.
Note: put the connection
wire into the right Sockets
(Please refer to 4.4 for
how to connect properly).
230 Volt
The Outlet is used to power
230v Single Phase 5oHz
loads requiring up to 1100W
continuous power.
Ground Terminal
Properly ground generator
to prevent electrical shock.
Connect the ground terminal
of generator to ground
electrode buried in the ground.
7.