2.3.3.
Event + Timer Mode and Messages
The event + timer mode combines the two modes so that it sends an uplink message
immediately each time a click type is applied on the button, and logs a count of the number
of clicks for each click type over a period of time and sends an uplink message at an uplink
frequency configured on the UnaConnect platform.
The uplink message for Event + Timer mode contains the following data:
● Message type: Event + Timer
● Sequence number: counter from 0 to 4095
● Uplink frequency: from 1 to 144 messages per 24 hours
● Summary of number of clicks detected: Edge, Single, Double, Long, Extra Long
2.3.4.
Event + Heartbeat Mode and Messages
In event + heartbeat mode, the device sends an uplink message immediately each time any
of the click type is applied on the button, and sends a heartbeat message at an interval
configured on the UnaConnect platform.
The heartbeat message contains battery voltage data to help monitor the batteries and
manage the device lifecycle in your operations.
The uplink message for Event + Heartbeat mode contains the following data:
● Message type: Event + Heartbeat
● Sequence number: counter from 0 to 4095
● Battery voltage: remaining voltage measured in mV
● Enabled detection type: Rising edge, Falling edge, Single, Double, Long, Extra Long
UnaBell LTE-M User Manual
18