  • Page 1 LUXURY SERIES OWNER’S MANUAL LX 11000 | LX 9000 | LX 7000 | LX 5000 Model # 1001,1002,1003,1004 P.N. 827114 11620 - 54th Street North Clearwater, FL 33760 (727) 573-9888 www.GulfCoastSpas.com...
  • Page 2 G U L F C O A S T S P A S A F F I L I A T I O N S...
  • Page 3: Table Of Contents

    T A B L E O F C O N T E N T S TABLE OF CONTENTS…………………...………………………………………….…….…………...……….3 INTRODUCTION…………………………….……………………………………………..……………………4 IMPORTANT SAFETY INSTRUCTIONS..………………….….…………………….………….…….……...….5 INSTALLATION……………………………...………………………………………….…….………………….9 ELECTRICAL SPECIFICATIONS……………………………………………………………..………….…10 STARTUP PROCEDURES…………………………………………………………………………….…….…..17 AQUACLARA NATURAL WATER MANAGEMENT SYSTEM…….………………………..…...…….…..25 FREQUENTLY ASKED QUESTIONS……………………………………………………………..….…….…...26 TROUBLESHOOTING GUIDE….……….……………………………………………………………….…….28 MAINTENANCE and CARE…………………………………………...………………………….…….……29 SHUTDOWN / WINTERIZING PROCEDURES ………………………………….………………..……….…31 LUXURY SERIES SPECIFICATIONS……………………………………………………………………………32 WARRANTY…………………………………………………………..…….…………..………………….…..38...
  • Page 4: Introduction

    THIS MANUAL AND ITS CONTENTS ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALTHOUGH GULF COAST SPAS HAS PREPARED THIS MANUAL AS ACCURATE AND PRECISE AS POSSIBLE, WE WILL NOT BE LIABLE FOR LOSS, INJURY OR DAMAGES CAUSED BY IMPROPER INSTALLATION OR...
  • Page 5: Important Safety Instructions

    I M P O R T A N T S A F E T Y I N S T R U C T I O N S When installing your spa and using this equipment, always follow basic safety precautions including the following: READ AND FOLLOW ALL INSTRUCTIONS! DANGER!: TO REDUCE THE RISK OF INJURY, do not permit children to use this product unless...
  • Page 6 WARNING SIGN MUST BE POSTED The (red) WARNING sign above is packed with your new Gulf Coast spa. This sign must be posted in a prominent place in close proximity to the spa installation site immediately upon completion of spa installation. WARNING SIGN –...
  • Page 7 DANGER! – RISK OF ELECTRICAL SHOCK: Install at least 6 feet (91.5m) from all metal surfaces. As an alternative, a spa may be installed within 5 feet (1.5m) of metal surfaces if each metal surface is permanently connected by a minimum No. 6 AWG (10mm2) solid copper conductor to the wire connector on the terminal box that is proved for this purpose.
  • Page 8 CAUTION! – Always test the spa water temperature before entering the spa. Enter and exit the spa slowly. Wet surfaces can be very slippery. Never bring any electrical appliances into or near the spa, with the exception of a space heater used for winterizing/troubleshooting ONLY.
  • Page 9: Installation

    I N S T A L L A T I O N Proper planning is an important consideration when installing your new spa. Site selection is a critical step and should be given some serious thought. Planning ahead, before the delivery of your spa, will make the process of installation easier.
  • Page 10: Electrical Specifications

    E L E C T R I C A L S P E C I F I C A T I O N S IMPORTANT! Qualified and licensed electricians must perform all electrical hookups. The following specifications must be followed in order to ensure proper performance and safety. CAUTION! Failure to abide by specifications listed may result in damage to the equipment and may void the warranty.
  • Page 11 Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
  • Page 17: Startup Procedures

    S T A R T U P P R O C E D U R E S IMPORTANT!: Read these step-by-step startup procedures before starting your spa. Failure to follow any of these steps listed may result in damage to the equipment and may void the warranty.
  • Page 18 Turning the power on and activating the jets. Turn on the power to the hot tub at the house circuit breaker. The GFCI circuit breaker must be tested before each use of the spa. Press the “Test” button on the breaker and the circuit breaker should go to the tripped position.
  • Page 19 Activating the air blower (if equipped). Press the Blower key to turn on the air blower. Check if air goes to air jets on the butt/bottom of each seat. Press the Blower key again to turn the Blower off. A built-in timer automatically turns the Blower off after 20 minutes, unless it manually has been deactivated first.
  • Page 22 Turning on the light. Press the Light key to turn the spa Light on. Verify the spa Light is on. Press the Light key a second time to turn the spa Light off. A built-in timer automatically turns the spa Light off after two hours, unless the spa Light manually has been deactivated first.
  • Page 23 temperature setting is 95ºF. In water temperature regulation mode, the system first generates water flow through the heater housing and the plumbing to ensure accurate water temperature reading as well as avoiding heater activation in dry conditions. After verifying pump activation and taking a water temperature reading if required, the system automatically turns the heater on to reach and maintain water temperature at the set point.
  • Page 24 to change the setting. The default setting is ºF. Press the Light key a last time to save changes and return to normal mode. Using Smart Winter Mode (SWM) If the system (sensor located inside controller) detected ambient conditions below 42ºF, it automatically will activate the SWM for period of 24 hours.
  • Page 25: Aquaclara Natural Water Management System

    N A T U R A L HASSLE-FREE … NATURALLY SOFT SPA WATER … STABLE PH AND ALKALINITY Gulf Coast Spas now offers an enzyme-based water purification system for your spa. AquaClara Natural naturally solves most spa water treatment problems and dramatically reduces spa maintenance.
  • Page 26: Frequently Asked Questions

    Call our service department at (727) 573-9888. What happens when my warranty is expired? Gulf Coast Spas will continue to provide service for your spa after your warranty has expired via the 24/7 technical support hotline – (727) 573-9888.
  • Page 27 How do I use aromatherapy? Remove scented bead cartridge from plastic cover. Twist off aromatherapy injector valve cap on top of spa. Insert scented bead cartridge. Replace cap and tighten. (Turning on the blower activates the aromatherapy via the air injectors.) How do I use the audio system? (If equipped) To engage the two pop-up speakers in the spa corners,...
  • Page 28: Troubleshooting Guide

    T R O U B L E S H O O T I N G G U I D E Gulf Coast Spa Manufacturers always has endeavored to represent spas that are second to none in terms of quality. Problems may arise that may or, or may not require service. If a problem does arise, check the following troubleshooting guide for a solution.
  • Page 29: Maintenance And Care

    This will ensure that the water is being filtered properly, and there is no restriction in the filters due to dirt and grease. DO NOT BLEACH. Gulf Coast Spas recommends having replacement filters on hand, that can be swapped between cleanings.
  • Page 30 SPA COVER – The 5-inch thick tapered cover on your spa is made from a weatherproof marine vinyl. Your cover will last much longer if you heed the following suggestions: 1) Don’t drag the cover on the ground; wearing of the vinyl could easily develop into a tear. 2) The insulating foam in your cover is not designed to hold the weight of a person or an animal.
  • Page 31: Shutdown / Winterizing Procedures

    S H U T D O W N W I N T E R I Z I N G P R O C E D U R E S Special accessories that may be needed to facilitate long-term shutdown: quick drain or sump pump, wet/dry vacuum, small electric space heater (must be used in cold weather).
  • Page 32: Luxury Series Specifications

    LX 11000...
  • Page 33 LX 9000...
  • Page 34 LX 7000...
  • Page 35 LX 5000...
  • Page 36 C O N D I T I O N S W A R R A N T I E S All limited warranties provided hereunder extend only to the original consumer/purchaser of the spa if purchased and installed within the boundaries of the United States or Canada and terminate upon transfer of ownership from original consumer/purchaser.
  • Page 37 *Option 3 – Customer can elect overnight shipping directly to them with minimal expense. The arrival of the replacement component(s) would be next day. This option can take 1-2 days. When you call, please have your serial number ready and have access to your spa. Your spa has self monitoring diagnostic capabilities and you will need to be able to read these to your Gulf Coast Spa Services support representative (please stand next to spa when calling).
  • Page 38: Warranty

    PERFORMANCE: To obtain service in the event of a defect covered by this Limited Warranty, call the Gulf Coast Spas 24/7 technical support line at (727) 573-9888 as soon as possible and use all reasonable means to protect the spa from further damage.
  • Page 39 I M P O R T A N T W A R R A N T Y I N F O R M A T I O N The warranty card MUST be filled out completely and mailed within 30 days of purchase to validate warranty. Please make a copy before mailing. MAIL TO: Gulf Coast Spas Attn: Technical support 11620 54 St. N. Clearwater, FL 33760...