Output Characteristics
Digital Output Logic Levels at 8 mA loads
High .................................................................. 4.0 V to 5.0 V
Low................................................................... 0.1 V to 0.4 V
Input Characteristics
Differential Input Logic Levels
High .................................................................. (a - b) > 200 mV
Low................................................................... (a - b) < -200 mV
Physical Specifications and Characteristics
Weight............................................................... 170 g
Maximum Altitude ........................................... 2000 m
Maximum Ambient Temperature ..................... 70 ºC
Operating Humidity.......................................... 10% to 90% RH, noncondensing
Pollution Degree ............................................... 2
Ingress Protection ............................................. IP40
For indoor use only.
If you need to clean the module, wipe it with a dry towel.
Safety Guidelines
Caution
instructions. Product misuse can result in a hazard. You can compromise the safety
protection built into the product if the product is damaged in any way. If the product
is damaged, return it to National Instruments for repair.
Do not operate the NI 9753 in a manner not specified in these operating
NI 9753 User Manual | © National Instruments | 7