1(3) DATA SHEET Manual Call Point IP67 Salwico MCP-C WP (GB) Part no. 5200014-01A System: Salwico Cargo, Salwico Cruise, Salwico Workboat, Salwico Yacht, Salwico RoPax, CS4000, ServoFighter, C300, C303, C308, C316 General Description Connection The MCP-C is a manual call point for outdoor environment and is designed for the Salwico conventional fire alarm systems.
Pull cover away from the back box. Change Glass The specifications described herein are subject to change without notice. Data sheet no. 5200014-01A MCP-C WP.12 1.ME www.consilium.se...
3(3) DATA SHEET Dimensions (mm) The specifications described herein are subject to change without notice. Data sheet no. 5200014-01A MCP-C WP.12 1.ME www.consilium.se...
Page 5
Dimensions (mm) Specifications may be subject to change for improvement without prior notice Data sheet no: 46950.03.1.E Consilium Marine AB ÇConsilium P.O. Box 8763, SE-402 76 Göteborg, Sweden Phone +46 31 710 77 00 Fax +46 31 710 78 00...
LED – + – + Specifications may be subject to change for improvement without prior notice Data sheet no: N1115.06.1.E Consilium Marine AB ÇConsilium P.O. Box 8763, SE-402 76 Göteborg Phone +46 31 7107700 Fax +46 31 7107800 www.consilium.se...
Page 7
Cable dimension Ø6-14 mm 6 and 8 (for servofighter) according to Certified according to system specification. 0832 Part no. Spare glasses (10pcs.) 5200075-00A The specifications described herein are subject to change without notice. Data sheet no. 5200010-01A MCP-C.12 1.ME www.consilium.se...
Page 8
2(3) DATA S H E ET Test Change Glass Dimensions (mm) The specifications described herein are subject to change without notice. Data sheet no. 5200010-01A MCP-C.12 1.ME www.consilium.se...
Page 9
3(3) DATA SHEET Mounting Dimensions (mm) The specifications described herein are subject to change without notice. Data sheet no. 5200010-01A MCP-C.12 1.ME www.consilium.se...
Page 10
5200237-00A Salwico AC-IR-3Fq Addressable Base • Easy Maintenance Test Equipment • Remote LED Option 001156 Salwico IR Test lamp • Approved to UNI EN54-10 Ed. 2002 The specifications described herein are subject to change without notice. Data sheet no. 5200236-00A_Salwico AC-IR-3Fq_M_EN_2014_E www.consilium.se...
(FOV). • The DIP-Switch Setting recommended by This includes glass, Plexiglas and other visibly Consilium is to turn Sw.No.2 ON for the transparent materials. Contact Consilium for highest sensitivity. For more details, see more information.
Page 12
Only when used with Base 5200235-00A. Table 3. Addressable Mode Mode Sw.No.3 Sw.No.4 Addressable** Only when used with Base 5200237-00A. * Recommended setting by Consilium ** Default factory setting The specifications described herein are subject to change without notice. Data sheet no. 5200236-00A_Salwico AC-IR-3Fq_M_EN_2014_E www.consilium.se...
1(2) DATA S H E E T Base Adapter SPB-ADAPT Part no. 046916 System: All Salwico Fire Alarm Systems General Description Dimensions (mm) SPB-ADAPT is an adapter for the bases 2IP55 (part. no. 046950) and NS-2IP55 (part no. 046900). SPB-ADAPT is developed to replace the adapters SPB-1 (part no.
Page 14
DATA S H E ET 2(2) Connection Connection of addressable detectors IA, OA, TDT and EV-PP series: Connection of addressable detectors NS, CN and EV-series** (EV-PP excluded): Connection of conventional detectors DIS3, DOS3, HC100,NS-DIR and NS-DUV: Connection of conventional flame detectors EVC-IR (not NS-DIR or NS-DUV): * All types of detectors do not have the remote output.
Need help?
Do you have a question about the Salwico MCP-C WP and is the answer not in the manual?
Questions and answers