Download Print this page

Cooper Lighting 1486 Specification Sheet

Cooper lighting cleanroom lighting specification sheet

Advertisement

Quick Links

FAIL-SAFE
CHF
CHG
2 5 0 W - 4 0 0 W
M e t a l H a l i d e
2 5 0 W - 4 0 0 W
H i g h P r e s s u r e S o d i u m
1 6 5 W
Q L I n d u c t i o n
H . I . D . F L A N G E / G R I D
O n e - P i e c e D o o r
• One-piece, clear prismatic,
tempered Corning lens
with internal prism pattern.
See Lens Options
• Die-formed, 18 ga. CRS
housing. Standard white
high reflectance polyester
powder coat finish
• Lamps by others
• Particulock™ lens retention
system utilizes 18 ga.
media clampdowns
• Two braided, stainless steel
cables provide hinging
• One piece, 18 ga. door with
baked white polyester
powder coat, fully
gasketed, outside door
• Copper wound, HPF ballast
is standard
• White, closed cell,
Flexiseal™ gasketing
system
• Gasketed access plate with
two flattened, 7/8" diameter
knockouts
1486
COOPER LIGHTING
®
D E S C R I P T I O N
The Fail-Safe CHF and CHG
Series are designed to deliver
highly efficient H.I.D. lighting
to clean areas. These units are
ideal for ceiling heights up to
18'. Lower wattages are also
available for standard 8' and 9'
ceilings. Units are enclosed
and gasketed to protect
against the chance of foreign
matter entering high tech
environments through the light
fixture. CHF outside flanged
door is designed to work with
conventional sheet rock or
plaster ceilings. The CHG
housing and door are designed
to work with standard 1" and
1 1/2" T-grid ceilings and most
2" T-grid ceilings. Door frames
feature a gasket design which
eliminates ledge or crevice
exposure preventing the
harboring of contaminants.
These luminaires are U.L.
listed and C.S.A. certified for
wet locations and are
manufactured in accordance
with U.S.D.A., F.D.A., N.S.F.
and Federal Standard 209E.
200 PSI Hose Down Rating is
standard. The CHF and CHG
Series are suitable for use in
I.E.S. Class 100, 1,000, 10,000
and 100,000 clean room
environments.
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : C H F - 2 5 0 S - 2 7 7 - 7 3 - S S N - S H N
Product Family
Metal Halide
CHF=H.I.D.
250M=250W
Flange
400M=400W
Type
High Pressure Sodium
CHG=H.I.D.
250S=250W
Grid Type
400S=400W
Induction
165Q=165W QL
Notes: For additional options, consult your Cooper Lighting Representative. Specifications and Dimensions subject to change
without notice.
1
Available with 240V. For other voltages, consult your sales representative.
dimensional details.
D I M E N S I O N S
B
B
M O U N T I N G
C
C
D
D
D O O R F R A M E
S H O W N W I T H 1 1 / 2 " T- G R I D
CHF
Flange Type
One-Piece Door
A
CHF
14 1/4"
(362mm)
CHG
14 1/2"
(368mm)
Voltage
Lens Type
93=Prismatic
120=120V
Tempered Glass
277=277V
(standard)
MT=Multi-tap
93/85=.156 Prismatic
120/208/
Tempered
240/277V
Glass with .187
Clear
Polycarbonate
1
Underlay
A
A
B
B
B
B
C
C
CHG
Grid-Type
One-Piece Door
B
C
D
22 5/8"
19 1/2"
23" sq.
(575mm)
(495mm)
(584mm)
23 11/16"
23 3/4"
(602mm)
(603mm)
Options
Door/Finish Options
2TE=Accommodates 2" T-
Blank=Standard, CRS
with baked white
finish
SSN=Stainless Steel
Door/Brushed 304
SF=Single Fuse
Finish
DF=Double Fuse
SSP=Stainless Steel
QS=Quartz Socket
Door/Polyester
Powder Coat Finish
QRS=Quartz Restrike
ALP=Aluminum
Door/Polyester
Powder Finish
TAD=Top Access Door
Housing Options
SHN=Stainless Steel,
SHP=Stainless Steel,
ALH=Aluminum, Polyester
2
Consult your Cooper Lighting Representative for
A
A
Grid (use with 24"
width only. Consult
Cooper Lighting
Representative.)
(DC bayonet base)
System
2
Brushed 304 Finish
Polyester Powder
Finish
Powder Finish

Advertisement

loading

This manual is also suitable for:

ChfFail-safe chf seriesFail-safe chg series