Nooploop product would cause severe personal injury or death. Nooploop customers using or selling Nooploop products in such a manner do so entirely at their own risk and agree to fully indemnify Nooploop and its representatives against any damages arising out of the use of Nooploop products in such safety-critical applications.
Page 4
According to IEC 60825-1:2014 Safety of laser products - Part 1:Equipment classification and requirements. The maximum output laser power of the product is 50.5uW. The TOFSense series products comply with the Class 1 laser product standard specified in GB ...
TOFSense P/TOFSense PS modules output at a frequency of 30Hz. The output format follows the NLink_TOFSense_Frame0 protocol. To connect the TOFSense series products to the NAssistant software via a USB to TTL module (reference the data manual for the wire sequence and power supply voltage), after successful recognition, click on the settings page .
The CAN active output mode can be used in single module and cascaded configurations. In this mode, the TOFSense module outputs measurement information at a frequency of 10Hz, while TOFSense P/TOFSense PS modules output at a frequency of 30Hz, and the output format follows the NLink_TOFSense_CAN_Frame0 protocol.
NLink_TOFSense_CAN_Read_Frame0 protocol, and the output frame format follows the NLink_TOFSense_CAN_Frame0 protocol. To connect TOFSense series products to the NAssistant software via a USB to TTL module (referring to the data manual for wiring and power voltage), after successful identification, click to enter the setting page .
When the module is in UART mode (note that NAssistant cannot recognize modules in I/O mode), TOFSense series products can be connected to the NAssistant software via a USB to TTL module (referring to the data manual for wiring and power voltage). After successful identification, click to enter the setting page .
Firmware" to load the latest public version firmware after switching to other firmware). Click "Test Version Firmware" and enter the firmware test code obtained from Nooploop's official website in the pop-up window. Click "OK" to load the corresponding test version firmware.
Cascade Ranging available. Users should choose the appropriate FOV angle based on their actual scene. Figure 10 : The maximum ranging distance of TOFSense is related to the field of view (FOV) 7 Cascade Ranging Multiple sensors can be configured with different IDs and connected in series, and the ranging information of all sensors can be read through a single communication interface.
However, if two modules are at the same horizontal height and facing each other, the measurement may be affected for both of them. Q3. Why is there no data output from TOFSense? Each module has undergone strict testing before shipping. If there is no data, please first check if...
Page 16
UART mode on the settings page and write the parameters into the module through the host computer. For TOFSense-PS, in CAN mode, you can use a USB-to-TTL module to connect to the host computer. Change the baud rate to 921600 and connect it to the corresponding port of the USB-to-TTL module.
Reference TOFSense series port does not contain a 120R matching resistor, so make sure that the resistance of the query device matches. Finally, check whether the format of the sent query frame meets the NLink_TOFSense_CAN_Read_Frame0 protocol, and pay special attention to the correct standard frame ID.