Baxi HP40-XX-MB Operation Manual page 31

Wired controller
Table of Contents

Advertisement

T4_AHS_on
237 (PLC: 40238)
dT1_AHS_on
238 (PLC: 40239)
t_AHS_delay
240 (PLC: 40241)
t_DHWHP_max
241 (PLC: 40242)
t_DHWHP_restrict
242 (PLC: 40243)
T4autocmin
243 (PLC: 40244)
T4autohmax
244 (PLC: 40245)
T1S_H.A_H
245 (PLC: 40246)
T5S_H.A_DHW
246 (PLC: 40247)
ECO parameter
247 (PLC: 40248)
ECO parameter
248 (PLC: 40249)
ECO parameter
249 (PLC: 40250)
ECO parameter
250 (P LC:40251)
Comfort parameter
251 (PLC: 40252)
Comfort parameter
252 (P LC:40253)
Comfort parameter
253 (PLC: 40254)
Comfort parameter
254 (P LC:40255)
t_DRYUP
255 (PLC: 40256)
t_HIGHPEAK
256 (PLC: 40257)
t_DRYD
257 (PLC: 40258)
T_DRYPEAK
258 (PLC: 40259)
t_firstFH
259 (PLC: 40260)
T1S (first floor heating)
260 (PLC: 40261)
T1SetC1
261 (PLC: 40262)
T1SetC2
262 (PLC: 40263)
T4C1
263 (PLC: 40264)
T4C2
264 (PLC: 40265)
265 (PLC: 40266)
T1SetH1
T1SetH2
266 (PLC: 40267)
T4H1
267 (PLC: 40268)
T4H2
268 (PLC: 40269)
Ambient temperature for enabling the external heater AHS, range:
-15~10°C, setting interval: -5°C
Temperature return difference for enabling the external heater AHS,
range: 2~10°C; default setting: 5°C
Delay time for enabling the external heater AHS, range: 5~120 min;
default setting: 30 min
Longest duration of water heating by the heat pump, range:
10~600 min, default setting: 120 min;
Duration of limited water heating by the heat pump, range:
10~600 min, default setting: 30 min;
Default setting: 25°C, range: 20~29°C, setting interval: 1°C
Default setting: 17°C, range: 10~17°C, setting interval: 1°C
In the holiday mode, setting of T1 in the heating mode, range:
20~25°C, default setting: 25°C
In the holiday mode, setting of T1 in the water heating mode, range:
20~25°C, default setting: 25°C
Reserved, wrong address is reported when this register is queried
Reserved, wrong address is reported when this register is queried
Reserved, wrong address is reported when this register is queried
Reserved, wrong address is reported when this register is queried
Reserved, wrong address is reported when this register is queried
Reserved, wrong address is reported when this register is queried
Reserved, wrong address is reported when this register is queried
Reserved, wrong address is reported when this register is queried
Temperature rise day number, range: 4~15 days, default setting:
8 days
Drying day number, range: 3~7 days, default setting: 5 days
Temperature drop day number, range: 4~15 days, default setting:
5 days
Highest drying temperature, range: 30~55°C, default setting: 45°C
Running time of floor heating for the first time, default setting:
72 hrs, range: 48-96 hrs
T1S of floor heating for the first time, range: 25~35°C, default setting:
25°C
Parameter of the ninth temperature curves for cooling mode,
range:5~25°C, default setting: 10°C;
Parameter of the ninth temperature curves for cooling mode,
range:5~25°C, default setting: 16°C;
Parameter of the ninth temperature curves for cooling mode, range:
(-5)~46°C, default setting: 35°C;
Parameter of the ninth temperature curves for cooling mode, range:
(-5)~46°C, default setting: 25°C;
Parameter of the ninth temperature curves for cooling mode,
range:25~60°C, default setting: 35°C;
Parameter of the ninth temperature curves for cooling mode,
range:25~60°C, default setting: 28°C;
Parameter of the ninth temperature curves for cooling mode, range:
(-25)~30°C, default setting: -5°C;
Parameter of the ninth temperature curves for cooling mode, range:
(-25)~30°C, default setting: 7°C;