Customer Care Europe, Middle East & Africa
SCCE Training Group
Example of a broken Flash D450:
Different battery connectors
There are two different battery connectors with the same part code 5400239 (see pictures below).
If it is necessary to exchange the battery connector X101/ X102, take care that you use the corresponding part.
Wrong replacement causes switch-off trouble.
Different surface, width and position of spring contacts:
Difference
Note! It is not allowed to use the battery connectors of NPE-3 (part code 5469069) because of smaller size.
Auto power off
The phone turns off, because the contact pads on the battery and the battery connectors are worn out so that the
phone has lost the contact to the battery.
Assemble the Y- and Z-Pads, as in the picture below.
For more information see SB-010 (NPE-4).
© NMP 2003
CONFIDENTIAL
NPE-4 6310/NPL-1 6310i
Date 22.04.2003
Difference
Difference
Checked by:
SCCE Training Group
8 (29)
Repair Hints
Version 3.0 Approved
Difference
Battery Pad Y
Battery Pad Z
Approved by:
SCCE