Nokia 6310 Manual page 15

Hide thumbs Also See for 6310:
Table of Contents

Advertisement

Customer Care Europe, Middle East & Africa
SCCE Training Group
Make the following measurements in burst mode with an oscilloscope in DC mode.
Oscilloscope settings:
Ampl:
200mV
Time/Div:
1ms/Div
AC/DC/GND:
DC
If not ok, check 67.71 kHz at C714 (DtoS and Biquad filter).
Order of measurement points at C714 (counted from N600 Hagar side):
Oscilloscope settings:
Ampl:
500mV
Time/Div:
200µs/Div
AC/DC/GND:
DC
If the signal is not ok, check in GSM the RX signal 942.4 MHz at channel 37, RF level –55 dBm at L626.
If the signal is not ok, check in PCN the RX signal 1842.4 MHz at channel 700, RF level –55 dBm at L616
If both RX signals not ok, check RX lines from N600 Hagar to X802 antenna connector for shorts or
disconnections.
Check the following voltages:
Check VR4 = 2.8 VDC at C601
Check VR5 = 2.8 VDC at C604
Check VR6 (VBB) = 2.8 VDC at C605
Check VR1A (VCP) = 4.7 VDC (supply for control voltage VC for SHF oscillator) at C600
Check VR7 = 2.8 VDC at C299 (supply voltage VCC for SHF oscillator)
Check VREF01 and VREF02 = 1.35 VDC at R726
- If one of the voltages described above is not ok, check UEM D200.
© NMP 2003
CONFIDENTIAL
NPE-4 6310/NPL-1 6310i
Date 22.04.2003
DtoS
Checked by:
SCCE Training Group
Repair Hints
Version 3.0 Approved
pins (3/4)= DtoS I/Q;
pins (1/2)= Biquad (CM_F and CP_F I/Q).
Biquad
Approved by:
SCCE